Powered by GoogleTranslate

Inspection Detail

Inspection: 302041603 - Cherry Electric Corporation

Inspection Information - Office: Chicago North Area Office

 

Inspection Nr: 302041603
Report ID: 0524200
Date Opened: 05/13/1998

Site Address:
Cherry Electric Corporation
3600 Sunset Avenue
Waukegan, IL 60087

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3679

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/07/1998

Emphasis:

Case Closed: 06/30/1999


Related Activity
Type Activity Nr Safety Health
Accident 101260420
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 5
Current Violations
Initial Penalty $7,150 $0 $0 $0 $0 $7,150
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100303 B01 09/11/1998 09/18/1998 $1,300 $1,300 $0 10/05/1998 F - Formal Settlement Citation has been deleted.
2. 01002 Serious 19100304 A03 09/11/1998 09/18/1998 $1,625 $1,625 $0 10/05/1998 F - Formal Settlement Citation has been deleted.
3. 01003 Serious 19100304 F04 09/11/1998 09/18/1998 $1,300 $1,300 $0 10/05/1998 F - Formal Settlement Citation has been deleted.
4. 01004 Serious 19100332 B02 09/11/1998 09/30/1998 $1,300 $1,300 $0 10/05/1998 F - Formal Settlement Citation has been deleted.
5. 01005A Serious 19100334 A02 III 09/11/1998 09/17/1998 $1,625 $1,625 $0 10/05/1998 F - Formal Settlement Citation has been deleted.
6. 01005B Serious 19100334 A03 II 09/11/1998 09/18/1998 $0 $0 $0 10/05/1998 F - Formal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 302041603
Event: 05/12/1998
electric shock - ground fault in attachment plug

An employee finished setting up a plastic molding machine and was preparing to run sample parts to verify correct operation of the machine. He plugged the attachment plug for the machine's cooling-water pump unit into a twist-lock receptacle outlet, which was defective. The improperly aligned attachment plug caused the equipment grounding conductor for the pump to be connected to the ungrounded circuit conductor energizing the housing of the pump unit. When the employee contacted the energized housing of the pump unit, he was electrocuted.

Keywords: E GI V, RECEPTACLE, ELECTRICAL, ELECTROCUTED, ATTACHMENT PLUG, ELECTRIC PUMP, GROUND FAULT, EQUIPMENT GROUNDING

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 302041603 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close