Powered by GoogleTranslate

Inspection Detail

Inspection: 301951117 - Grand Cove Marina Inc.

Inspection Information - Office: Hasbrouck Heights Area Office

 

Inspection Nr: 301951117
Report ID: 0214500
Date Opened: 05/21/1998

Site Address:
Grand Cove Marina Inc.
989 River Road
Edgewater, NJ 07023

Mailing Address:
523 River Road, Edgewater, NJ 07020

Union Status: NonUnion

SIC:4493

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/12/1998

Emphasis:

Case Closed: 08/26/1998


Related Activity
Type Activity Nr Safety Health
Accident 101380160
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 4 4
Initial Penalty $3,750 $0 $0 $0 $0 $3,750
Current Penalty $3,750 $0 $0 $0 $0 $3,750
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100303 G02 I 08/12/1998 08/17/1998 $750 $750 $0 -  
2. 01002A Serious 19100304 A02 08/12/1998 08/17/1998 $1,500 $1,500 $0 -  
3. 01002B Serious 19100304 A03 08/12/1998 08/17/1998 $0 $0 $0 -  
4. 01003 Serious 19100304 E01 I 08/12/1998 08/17/1998 $750 $750 $0 -  
5. 01004 Serious 19100304 F04 08/12/1998 08/17/1998 $750 $750 $0 -  

Investigation Summary

Investigation Nr: 201380177
Event: 05/20/1998
electric shock - ground fault in sump pump

An employee for a marina was using a Simer Geyser Submersible Utility Pump to pump out the bilge of a work barge. The pump was equipped with float switch and was connected via an extension cord to a dockside 125-volt receptacle outlet. The receptacle was improperly wired with the line and neutral connections reversed. Also, the cord set had been repaired and the receptacle cord cap was missing the equipment grounding prong. The employee was electrocuted when he stepped into the water-filled bilge of the barge and contacted a grounded surface. (The employee also had second-degree electrical burns on his back and above his right eye.)

Keywords: RECEPTACLE, ELECTRICAL, REVERSE POLARITY, CORD SET, E GI VII, ELECTROCUTED, GROUND FAULT, EQUIPMENT GROUNDING, PUMP

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 301951117 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close