Inspection Detail
Inspection: 301890315 - Diesel Energy Systems & Service, Inc.
Inspection Information - Office: Fort Lauderdale Area Office
Site Address:
Diesel Energy Systems & Service, Inc.
46 Beach Road
Tequesta, FL 33469
Mailing Address:
231 Juno Street, Jupiter, FL 33458
Union Status: NonUnion
SIC:7699
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/16/1999
Emphasis:
Case Closed: 05/18/2000
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 100672583 |
Investigation Summary
A diesel mechanic was replacing an air conditioning feed-water pump in the port engine room of a yacht. He was found slumped over the engine with a volt-ohmmeter ready for use and the newly installed pump operating. He had been electrocuted. A subsequent examination of the pump revealed an error in the wiring. Apparently, the employee had interchanged the neutral conductor and the equipment grounding conductor. The ground fault had electrocuted the employee.
Keywords: E GI V, REPAIR, ELECTRICAL, ELECTROCUTED, ELECTRIC PUMP, GROUND FAULT, EQUIPMENT GROUNDING, BOAT
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 301890315 | Fatality | Electric Shock | Bus, truck and stationary engine mechanics |
Translate