Inspection Detail
Inspection: 301875514 - L. G. Mclennan Drilling Company, Inc.
Inspection Information - Office: Oklahoma City Area Office
Site Address:
L. G. Mclennan Drilling Company, Inc.
2-3 Miles Nw Of #99 & Cr5305
Wynona, OK 74084
Mailing Address:
P.O. Box 6, Nowata, OK 74048
Union Status: NonUnion
SIC:1381
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/05/1998
Emphasis:
Case Closed: 04/06/1999
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361824154 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 2 | ||||
| Current Violations | 2 | 2 | ||||
| Initial Penalty | $3,000 | $0 | $0 | $0 | $0 | $3,000 |
| Current Penalty | $2,500 | $0 | $0 | $0 | $0 | $2,500 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 5A0001 | 07/01/1998 | 08/03/1998 | $1,250 | $1,500 | $0 | I - Informal Settlement | ||
| 2. | 01002 | Serious | 19100036 B02 | 07/01/1998 | 07/07/1998 | $1,250 | $1,500 | $0 | I - Informal Settlement |
Investigation Summary
Employees #1 through #4 were part of a crew drilling an oil well at a site northwest of Wynona, OK. They had removed the drill bit and placed it on the oil rig floor, and had put the last stand of 900 lb, 30 ft long drill pipe collars in the pipe rack when the Franks Explorer drilling rig collapsed. Employee #1, the derrickman, was killed. Employee #2, the driller, sustained back injuries and was hospitalized. Employees #3 and #4, both rig hands, suffered minor injuries and were treated and released that same day. The most likely cause of the accident was the load shifting. Subsequent investigation revealed that there was no escape device in the pipe rack, which was approximately 60 ft above the rig floor. Also, the wind gust anchors were not set in the proper location, the anchorage system was not appropriate for the job, and the rig was not properly maintained.
Keywords: DERRICKMAN, COLLAPSE, INADEQUATE MAINT, UNSECURED, WORK RULES, LOAD SHIFT, OIL WELL DRILLING, FALL, BRACING, OIL RIG
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 301875514 | Hospitalized injury | Other | Occupation not reported | ||
| 2 | 301875514 | Fatality | Other | Occupation not reported | ||
| 3 | 301875514 | Non Hospitalized injury | Other | Occupation not reported | ||
| 4 | 301875514 | Non Hospitalized injury | Other | Occupation not reported |