Powered by GoogleTranslate

Inspection Detail

Inspection: 301862652 - Mg Warehouse Inc

Inspection Information - Office: Or-E-Portland - Safety 1 1054111

 

Inspection Nr: 301862652
Report ID: 1054112
Date Opened: 10/20/1997

Site Address:
Mg Warehouse Inc
9700 N Hurst
Portland, OR 97217

Mailing Address:
Po Box 17009, Portland, OR 97217

Union Status: NonUnion

SIC:4225

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/21/1997

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 10/20/1999


Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 3 3
Initial Penalty $2,400 $0 $0 $0 $0 $2,400
Current Penalty $600 $0 $0 $0 $0 $600
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100303 G02 II 03/26/1998 10/21/1997 $0 $1,500 $0 04/14/1998 L - State Settlement  
2. 01002 Serious 19100178 L 03/26/1998 04/05/1998 $0 $300 $0 04/14/1998 D - Govt Dismissed Citation has been deleted.
3. 01003 Serious 701076001 A 03/26/1998 10/21/1997 $300 $300 $0 04/14/1998 L - State Settlement  
4. 01004 Serious 19100023 C01 03/26/1998 10/21/1997 $300 $300 $0 -  

Investigation Summary

Investigation Nr: 201630357
Event: 10/20/1997
burn - electrical fault in electrical cabinet

An employee was loading a distribution bin with salt. Using a forklift, he lifted a large bag of salt and dumped it into the bin. After dumping the salt, the employee backed the forklift from the bin without lowering the forks. The forklift tipped over. As it fell, its mast hit an unguarded, outside electrical cabinet and caused an electrical fault. The ensuing electric arc ignited the seat of the forklift. The employee, whose pants also ignited, was burned in the accident. He was hospitalized for his injuries.

Keywords: BURN, CLOTHING, ELECTRIC ARC, E GI III, ELECTRICAL, INDUSTRIAL TRUCK, ELECTRICAL CABINET, ELECTRICAL FAULT, OVERTURN

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 301862652 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.