Powered by GoogleTranslate

Inspection Detail

Inspection: 301774782 - Fuji Photo Film, Inc.

Inspection Information - Office: Sc Department Of Labor, Licensing, And Regulation

 

Inspection Nr: 301774782
Report ID: 0454510
Date Opened: 03/24/1999

Site Address:
Fuji Photo Film, Inc.
215 Pucketts Ferry Road
Greenwood, SC 29648

Mailing Address:
P O Box 1306, Greenwood, SC 29648

Union Status: NonUnion

SIC:3695

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 04/09/1999

Emphasis:

Case Closed: 03/13/2000


Related Activity
Type Activity Nr Safety Health
Accident 100370022
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations
Initial Penalty $3,750 $0 $0 $0 $0 $3,750
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100119 E03 05/05/1999 06/07/1999 $1,875 $1,875 $0 05/17/1999 D - Govt Dismissed Citation has been deleted.
2. 01002A Serious 19100119 C01 05/05/1999 06/07/1999 $1,875 $1,875 $0 05/17/1999 D - Govt Dismissed Citation has been deleted.
3. 01002B Serious 19100119 F01 05/05/1999 06/07/1999 $0 $0 $0 05/17/1999 D - Govt Dismissed Citation has been deleted.
4. 01002C Serious 19100119 L01 05/05/1999 06/07/1999 $0 $0 $0 05/17/1999 D - Govt Dismissed Citation has been deleted.

Investigation Summary

Investigation Nr: 800060
Event: 03/23/1999
Three employees injured when chemical mixture ignites

At approximately 9:00 a.m. on March 23, 1999, Employees #1 through#3 were starting the initial phase of a mixing operation. Employees #1 and #2 were reading the Standard Operating Procedure (SOP) while Employee #1 added the chemicals. The employees who were reading skipped two steps, which called for a nitrogen purge on the tank to reduce the oxygen level to below 4 percent. These steps were necessary because the last chemical to be added was a self-heating powder that oxidized rapidly in the presence of oxygen. When Employee #3 added the product in the presence of oxygen, a flash fire broke out and powder was blown from the vessel. This caused the overhead sprinklers to activate and the plant was evacuated. Employees #1 through #3 were transported to the hospital, where they were treated and released. The employer was cited for deficient operating procedures, deficient management of change procedures, and failure to have a written plan for employee evacuation.

Keywords: OXYGEN, DUST, WORK RULES, FIRE, INHALATION, CHEMICAL REACTION, POWDER, CHEMICAL, INATTENTION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 301774782 Non Hospitalized injury Other Mixing and blending machine operators
2 301774782 Non Hospitalized injury Other Mixing and blending machine operators
3 301774782 Non Hospitalized injury Other Mixing and blending machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.