Inspection Detail
Inspection: 301768404 - Bigham Cable Construction, Inc.
Inspection Information - Office: Sc Department Of Labor, Licensing, And Regulation
Site Address:
Bigham Cable Construction, Inc.
Saco Lowell Rd. & Lynn Court
Easley, SC 29640
Mailing Address:
17 Jenkins Court, Mauldin, SC 29662
Union Status: NonUnion
SIC:1731
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/11/1998
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 01/05/2011
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362625675 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 3 | ||||
| Current Violations | 3 | 3 | ||||
| Initial Penalty | $2,625 | $0 | $0 | $0 | $0 | $2,625 |
| Current Penalty | $1,050 | $0 | $0 | $0 | $0 | $1,050 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 10012 A | 05/19/1998 | 05/22/1998 | $350 | $875 | $0 | I - Informal Settlement | ||
| 2. | 01002 | Serious | 19260100 A | 05/19/1998 | 05/22/1998 | $350 | $875 | $0 | I - Informal Settlement | ||
| 3. | 01003 | Serious | 19260453 B02 V | 05/19/1998 | 05/22/1998 | $350 | $875 | $0 | I - Informal Settlement |
Investigation Summary
A crew of three cable television workers was lashing a cable television cable to a utility pole. One employee was in an aerial lift; another employee was on the ground assisting; and the third employee was about 0.4 kilometers away, directing traffic. The ground worker noticed the employee in the aerial lift slumped over in the bucket, lying on the controls unconscious. The aerial lift bucket was moving in the direction of an overhead power line. The employees on the ground could not safely reach the emergency shutoff. The bucket went into the power line, electrocuting the employee inside.
Keywords: UNCONSCIOUSNESS, OVERHEAD POWER LINE, ELECTRICAL, CABLE TV WORK, E TC, ELECTROCUTED, AERIAL LIFT CONTROLS, AERIAL LIFT
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 301768404 | Fatality | Electric Shock | Electronic repairers, communica. & indus. equip. |