Powered by GoogleTranslate

Inspection Detail

Inspection: 301515201 - Globe Manufacturing Co., Inc.

Inspection Information - Office: Nc Department Of Labor - Charlotte

 

Inspection Nr: 301515201
Report ID: 0453730
Date Opened: 07/08/1996

Site Address:
Globe Manufacturing Co., Inc.
3145 Northwest Blvd.
Gastonia, NC 28053

Mailing Address:
Po Box 2245, Gastonia, NC 28053

Union Status: NonUnion

SIC:2284

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 08/15/1996

Planning Guide: Health-Manufacturing

Emphasis:

Case Closed: 08/11/1997


Related Activity
Type Activity Nr Safety Health
Accident 362712812
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 2 1 3
Initial Penalty $2,888 $0 $0 $0 $0 $2,888
Current Penalty $2,166 $0 $0 $0 $0 $2,166
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100119 E01 09/17/1996 07/15/1997 $241 $963 $0 P - Petition to Mod Abatement  
2. 01001B Serious 19100119 F01 09/17/1996 07/15/1997 $0 $0 $0 P - Petition to Mod Abatement  
3. 01001C Serious 19100119 G01 I 09/17/1996 07/15/1997 $0 $0 $0 P - Petition to Mod Abatement  
4. 01001D Serious 19100119 J02 09/17/1996 07/15/1997 $0 $0 $0 P - Petition to Mod Abatement  
5. 01001E Serious 19100119 L01 09/17/1996 07/15/1997 $0 $0 $0 P - Petition to Mod Abatement  
6. 01002A Serious 19100120 Q03 IV 09/17/1996 09/23/1996 $1,925 $1,925 $0 -  
7. 01002B Serious 19100120 Q06 IIIA 09/17/1996 10/21/1996 $0 $0 $0 -  
8. 01002C Serious 19100165 B01 09/17/1996 10/21/1996 $0 $0 $0 -  
9. 02001 Other 19100037 F06 09/17/1996 01/02/1997 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 202074142
Event: 07/07/1996
Two employees overcome by toluene vapors

On July 7, 1996, Employees #1 and #2 and a coworker were working in the reclaim basement of Globe Manufacturing Co., Inc., when they noticed a mixture of toluene and water overflowing from a 250-gallon, open-top waste tank. The coworker was sent to get respirators while the other two descended further into the basement to stop the spill and to clean up the area. They were overcome by toluene vapors shortly after stopping the spill and lost consciousness. An organic vapor alarm alerted other plant employees, who initiated a rescue effort. They were able to rescue Employee #2 but could not immediately extricate Employee #1, who was covered with toluene. The local fire department finally rescued Employee #1. Both employees were transported by ambulance to the hospital, where Employee #2 was treated and released. Employee #1 was admitted for observation and further testing; he was released the following day. The workers did not realize that the ventilation system for the basement was being serviced and therefore was not operational. Employee #1, the lead person, was an employee of Globe; Employee #2 and the coworker worked for T & K Maintenance, a contracting company.

Keywords: UNCONSCIOUSNESS, WORK RULES, TOXIC ATMOSPHERE, INHALATION, TOLUENE, TOXIC FUMES, VENTILATION, SPILL, CHEMICAL VAPOR, POISONING

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 301515201 Hospitalized injury Poisoning(Systemic) Helpers, mechanics and repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close