Powered by GoogleTranslate

Inspection Detail

Inspection: 301335691 - S & S Foods, Llc

Inspection Information - Office: Monrovia District Office

 

Inspection Nr: 301335691
Report ID: 0950644
Date Opened: 07/21/2005

Site Address:
S & S Foods, Llc
1120 W Foothill Blvd
Azusa, CA 91702

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:5147

NAICS: 311612/Meat Processed from Carcasses


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/03/2006

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 09/19/2006


Related Activity
Type Activity Nr Safety Health
Accident 362597635
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $0 $0 $0 $850 $0 $850
Current Penalty $0 $0 $0 $850 $0 $850
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3942 A 01/10/2006 02/07/2006 $850 $850 $0 -  

Investigation Summary

Investigation Nr: 201800141
Event: 07/14/2005
Employee's Arm Is Fractured When Pulled Into Chain Drive

At 6:30 a.m. on July 14, 2005, Employee #1, a sanitation worker, was spraying water on the on floor in a cleaning operation at the employer's production area. His main duty was sanitizing the machines. The employer processed meat products. At the time of the incident, some machines in the area were still in operation in order to finish the production cycle. A supervisor told Employee #1 to wash the floor where the machines had been turned off. When Employee #1 pulled the water hose, he inadvertently lifted a guard off a sprocket and chain drive of an energized screw conveyor. The exposed sprocket and chain drive caught his coat and pulled it into the drive. He sustained a fracture to his arm when the pulling motion jerked his arm toward the point of operation. As a result, Employee #1 was hospitalized. The safety guard was put on pins but did not have any fastening device to secure it on the machine. The manufacturer of the screw conveyor was Prime Sales and Services, Inc.

Keywords: CHAIN, FRACTURE, FOOD PREPARATION, SCREW CONVEYOR, UNSECURED, CLEANING, CAUGHT BY, WATER HOSE, SPROCKET, ARM

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 301335691 Hospitalized injury Fracture Laborers, except construction
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close