Powered by GoogleTranslate

Inspection Detail

Inspection: 301333985 - Ronford Products

Inspection Information - Office: Monrovia District Office

 

Inspection Nr: 301333985
Report ID: 0950644
Date Opened: 01/21/2005

Site Address:
Ronford Products
1116 E 2nd St
Pomona, CA 90723

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:5093

NAICS: 423930/Recyclable Material Merchant Wholesalers


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/16/2005

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 12/28/2006


Related Activity
Type Activity Nr Safety Health
Accident 362600793
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 2 6
Current Violations 3 2 5
Initial Penalty $31,270 $0 $0 $5,335 $0 $36,605
Current Penalty $15,885 $0 $0 $0 $0 $15,885
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 02/18/2005 03/18/2005 $0 $5,000 $0 I - Informal Settlement Citation has been deleted.
2. 01002 Other 4650 D 02/18/2005 03/18/2005 $0 $335 $0 I - Informal Settlement  
3. 02001 Serious 4838 A 02/18/2005 03/04/2005 $2,025 $3,035 $0 I - Informal Settlement  
4. 03001 Other 3203 A 02/18/2005 03/04/2005 $0 $3,035 $0 08/22/2005 F - Formal Settlement  
5. 04001 Serious 3383 A 02/18/2005 03/04/2005 $1,260 $12,600 $0 08/22/2005 F - Formal Settlement  
6. 05001 Serious 3382 A 02/18/2005 03/04/2005 $12,600 $12,600 $0 08/22/2005 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201799145
Event: 01/17/2005
Employee Severely Burned While Cleaning Plastic Extruder

At approximately 9:35 a.m. on January 17, 2005, Employee #1 was fixing a plastic extruder machine, Welex Plastic Extruder, Model 650-24, Serial Number 251. It had been taken out of service due to a hydraulic problem that prevented the breaker plates from shifting and thus the extruder screens could not be cleaned. Because the extruder screens could not be cleaned the plastic material was left to solidify in the extruder barrel. Employee #1 was using personal protective equipment provided by the employer, safety glasses, gloves and a dust mask. He turned on the barrel heaters which heats the barrel to between 350 and 430 degrees Fahrenheit. He then began replacement of the hydraulic unit. Once the hydraulic unit was installed Employee #1 removed and cleaned the shifter plates. A slug of material had formed in the barrel between the screw and the breaker plates. The slug measured 13.5-in. long and 6-in. in diameter. He used a propane torch to heat the slug to loosen it since the internal heaters would not reach the area where the slug was. He then put some acrylic material in the extruder feed throat and started the screw. He wedged a pry bar between the side of the barrel and the material slug. The slug, hot vapors and burnt material spewed out of the barrel severely burning Employee #1. He was hospitalized with second-degree burns to his face, back, chest, hands and arms.

Keywords: BURN, CHEST, MAINTENANCE, PPE, BACK, ARM, FACE, HAND

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 301333985 Hospitalized injury Burn/Scald(Heat) Supervisors, extractive occupations
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close