Inspection Detail
Inspection: 301330569 - Kinetic Lighting Inc.
Inspection Information - Office: Monrovia District Office
Site Address:
Kinetic Lighting Inc.
2015 E. 1st Street
Los Angeles, CA 90033
Mailing Address:
3583 Hayden Ave., Culver City, CA 90232
Union Status: NonUnion
SIC:7389
NAICS: 561790/Other Services to Buildings and Dwellings
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/15/2003
Emphasis:
Case Closed: 09/19/2006
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362593717 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 1 | 3 | |||
| Current Violations | 3 | 3 | ||||
| Initial Penalty | $25,200 | $0 | $0 | $450 | $0 | $25,650 |
| Current Penalty | $0 | $0 | $0 | $1,350 | $0 | $1,350 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3638 A | 12/09/2003 | 01/05/2004 | $450 | $450 | $0 | 01/20/2004 | F - Formal Settlement | |
| 2. | 02001 | Other | 3638 E | 12/09/2003 | 01/05/2004 | $450 | $12,600 | $0 | 01/20/2004 | F - Formal Settlement | |
| 3. | 03001 | Other | 3646 B | 12/09/2003 | 01/05/2004 | $450 | $12,600 | $0 | 01/20/2004 | F - Formal Settlement |
Investigation Summary
On September 15, 2003, an employee, a Fire Chief had taken on the task of removing the header from the large door to the shop to raise it three inches. The header was welded at one end to the vertical support and bolted at the other end. It was also welded to three vertical braces above the header. The employee unbolted one end of the header, and used a cutting torch cut 2 of the 3 vertical braces from the top of the header leaving the center and the other welded end. The employee placed an extension ladder against the header and brace at the welded end and proceeded to cut the welded end expecting the remaining center welded brace to hold. When the end of the header was freed from the vertical support, the center brace did not hold the weight of the header and the header fell, along with the ladder and the employee. The employee sustained a serious back injury when he landed on the ladder. The employee was hospitalized and treated for back injury.
Keywords: FRACTURE, ELECTRICIAN, BACK, FALL, AERIAL LIFT
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 301330569 | Hospitalized injury | Fracture | Electricians |
Translate