Inspection Detail
Inspection: 301327532 - J.F Duncan Industries Inc.
Inspection Information - Office: Monrovia District Office
Site Address:
J.F Duncan Industries Inc.
9301 Stewart & Gray Road
Downey, CA 90241
Mailing Address:
, , 00000
Union Status: Union
SIC:2599
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/06/2002
Emphasis:
Case Closed: 08/09/2004
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362548828 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 4 | 7 | |||
| Current Violations | 3 | 3 | ||||
| Initial Penalty | $22,050 | $0 | $0 | $1,300 | $0 | $23,350 |
| Current Penalty | $0 | $0 | $0 | $625 | $0 | $625 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3273 A | 08/23/2002 | 09/12/2002 | $125 | $325 | $0 | 03/13/2003 | F - Formal Settlement | |
| 2. | 01002 | Other | 6151 C01 | 08/23/2002 | 09/12/2002 | $0 | $325 | $0 | 03/13/2003 | F - Formal Settlement | Citation has been deleted. |
| 3. | 01003 | Other | 3203 B01 | 08/23/2002 | 09/19/2002 | $0 | $325 | $0 | 03/13/2003 | F - Formal Settlement | Citation has been deleted. |
| 4. | 01004 | Other | 3203 B02 | 08/23/2002 | 09/12/2002 | $0 | $325 | $0 | 03/13/2003 | F - Formal Settlement | Citation has been deleted. |
| 5. | 02001 | Other | 23400016 C | 08/23/2002 | 09/12/2002 | $250 | $5,850 | $0 | 03/13/2003 | F - Formal Settlement | |
| 6. | 03001 | Other | 3556 A | 08/23/2002 | 09/12/2002 | $250 | $8,100 | $0 | 03/13/2003 | F - Formal Settlement | |
| 7. | 04001 | Serious | 25000025 | 08/23/2002 | 09/12/2002 | $0 | $8,100 | $0 | 03/13/2003 | F - Formal Settlement | Citation has been deleted. |
Investigation Summary
On April 8, 2002, Employee #1 was using a 120 Volt, Makita-Grinder (Serial Number 2779E) to grind a metal kitchen top. There was a flash, caused by an internal wiring short in the portable grinder. The flash struck the employee's right hand. The employee suffered an electric shock and fell to the floor. A coworker, who was in the same area, ran to help the employee, after seeing him fall to the floor. The coworker unplugged the grinder, and notified the management officials for help. The paramedics were called, and the employee was taken to the hospital. Employee #1 was hospitalized. The investigation revealed that the grinding tool's power supply cord was badly frayed and bare conductors were visible on the cord. There was a 3 in. long sleeve covering the bare conductors but flash traveled thru the sleeve and hit employee's right hand.
Keywords: GRINDER, ELECTRIC SHOCK, STRUCK BY, HAND
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 301327532 | Hospitalized injury | Electric Shock | Grinding, abrading, buffing & polishing mach. op's |