Inspection Detail
Inspection: 301317541 - Falcon Industries
Inspection Information - Office: Marlton Area Office
Site Address:
Falcon Industries
104 Taylor Street
Trenton, NJ 08638
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3542
NAICS: 0
Inspection Type: Referral
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/26/1997
Emphasis:
Case Closed: 12/02/1997
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 201770880 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 1 | 4 | |||
| Current Violations | 3 | 1 | 4 | |||
| Initial Penalty | $2,100 | $0 | $0 | $0 | $0 | $2,100 |
| Current Penalty | $2,100 | $0 | $0 | $0 | $0 | $2,100 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100147 C01 | 08/27/1997 | 10/15/1997 | $525 | $525 | $0 | - | ||
| 2. | 01002 | Serious | 19100212 A03 II | 08/27/1997 | 11/03/1997 | $525 | $525 | $0 | - | ||
| 3. | 01003 | Serious | 19100217 C02 IA | 08/27/1997 | 11/03/1997 | $1,050 | $1,050 | $0 | - | ||
| 4. | 02001 | Other | 19100217 E01 II | 08/27/1997 | 10/15/1997 | $0 | $0 | $0 | - |
Investigation Summary
Employee #1 was operating a full-revolution power press when his thumb was amputated.
Keywords: AMPUTATED, POWER PRESS, STRUCK AGAINST, THUMB, PRESS OPERATOR, PRESS
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 301317541 | Hospitalized injury | Amputation | Occupation not reported |
Translate