Inspection Detail
Inspection: 301160065 - Peach Flower Inc. Dba Sakura Garden
Inspection Information - Office: Savannah Area Office
Site Address:
Peach Flower Inc. Dba Sakura Garden
302 Commercial Drive
Savannah, GA 31406
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:5812
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 12/05/2000
Emphasis:
Case Closed: 11/21/2001
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 100901289 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 1 | 3 | |||
Current Violations | 2 | 1 | 3 | |||
Initial Penalty | $3,000 | $0 | $0 | $1,500 | $0 | $4,500 |
Current Penalty | $2,400 | $0 | $0 | $1,200 | $0 | $3,600 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001A | Serious | 19100133 A01 | 12/06/2000 | 12/22/2000 | $1,200 | $1,500 | $0 | I - Informal Settlement | ||
2. | 01001B | Serious | 19100138 A | 12/06/2000 | 12/22/2000 | $0 | $0 | $0 | I - Informal Settlement | ||
3. | 01001C | Serious | 19100132 D01 | 12/06/2000 | 12/22/2000 | $0 | $0 | $0 | I - Informal Settlement | ||
4. | 01002A | Serious | 19101200 E01 | 12/06/2000 | 12/22/2000 | $1,200 | $1,500 | $0 | I - Informal Settlement | ||
5. | 01002B | Serious | 19101200 G01 | 12/06/2000 | 12/22/2000 | $0 | $0 | $0 | I - Informal Settlement | ||
6. | 01002C | Serious | 19101200 H01 | 12/06/2000 | 12/22/2000 | $0 | $0 | $0 | I - Informal Settlement | ||
7. | 02001 | Other | 19040008 A | 12/06/2000 | 12/08/2000 | $1,200 | $1,500 | $0 | I - Informal Settlement |
Investigation Summary
At approximately 10:00 p.m. on the evening on August 4, 2000, Employee #1 was working in a kitchen. He poured Lewis Red Devil 100 percent lye drain opener into a floor drain that was clogged, then walked away. He had returned to check the drain when there was a splashback reaction from it. Employee #1 suffered chemical burns to his face, and was transported by his employer to a local hospital. He was then transferred to a burn center, where he died two weeks later.
Keywords: CAUSTIC, PPE, WORK RULES, CLEANING, CLOGGED, CHEMICAL REACTION, CHEMICAL BURN, CLEANING FLUID, SPILL, FACE
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 301160065 | Fatality | Burn(Chemical) | Cooks, except short order |