Powered by GoogleTranslate

Inspection Detail

Inspection: 301127437 - Pacific Scientific Energetic Materials Company

Inspection Information - Office: High Hazard Unit - Central

 

Inspection Nr: 301127437
Report ID: 0950663
Date Opened: 02/08/2007

Site Address:
Pacific Scientific Energetic Materials Company
3601 Union Rd.
Hollister, CA 95023

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:2892

NAICS: 325920/Explosives Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/07/2007

Emphasis:

Case Closed: 06/29/2009


Related Activity
Type Activity Nr Safety Health
Accident 362329955
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 1 6
Current Violations 2 3 5
Initial Penalty $46,125 $0 $0 $1,125 $0 $47,250
Current Penalty $18,000 $0 $0 $2,250 $0 $20,250
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 5194 G02 06/08/2007 07/11/2007 $750 $1,125 $0 07/23/2007 J - ALJ Decision  
2. 02001 Serious 3383 B 06/08/2007 07/11/2007 $9,000 $18,000 $0 07/23/2007 J - ALJ Decision  
3. 03001 Other 3384 A 06/08/2007 07/11/2007 $750 $3,375 $0 07/23/2007 J - ALJ Decision  
4. 04001 Serious 5189 D01 C 06/08/2007 07/11/2007 $0 $3,375 $0 07/23/2007 D - Govt Dismissed Citation has been deleted.
5. 05001 Other 5189 E01 06/08/2007 07/11/2007 $750 $3,375 $0 07/23/2007 J - ALJ Decision  
6. 06001 Serious 5189 F01 A2 06/08/2007 07/11/2007 $9,000 $18,000 $0 07/23/2007 J - ALJ Decision  

Investigation Summary

Investigation Nr: 201489572
Event: 02/08/2007
Employee Sustains Burns When Explosive Mixture Ignites

At approximately 7:20 a.m. on February 8, 2007, Employee #1 was working for a company that manufactured explosives. He was pouring a dry explosive powder, designated PE-179 by the company, from a metal tray into a conductive plastic cup, when the powder ignited. The powder burned rapidly, but it did not explode. The ensuing deflagration caused second- and third-degree burns and lacerations to Employee #1's wrists. He was hospitalized for his burns. He was protected from more serious injuries, because he was working behind a blast shield.

Keywords: BURN, EXPLOSIVES, EXPLOSIVE MIXING, EXPLOSION, LACERATION, WRIST

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 301127437 Hospitalized injury Burn/Scald(Heat) Explosives workers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close