Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Inspection Detail

Inspection: 301121182 - Miracle Method Bathroom Restoration

Inspection Information - Office: Ca Concord

 

Inspection Nr: 301121182
Report ID: 0950622
Open Date: 08/23/2002

Site Address:
Miracle Method Bathroom Restoration
1600 Aster Drive #53
Antioch, CA 94509

Mailing Address:
5702 Marsh Drive, Ste J, Pacheco, CA 94553

Union Status: NonUnion

SIC:1793

NAICS: 238150/Glass and Glazing Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/20/2002

Emphasis: S:Construction (Cship)

Close Case:02/10/2003


Related Activity
Type Activity Nr Safety Health
Accident 101480614
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 4 6
Current Violations 2 4 6
Initial Penalty $3,600 $0 $0 $400 $0 $4,000
Current Penalty $3,600 $0 $0 $400 $0 $4,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 5144 C 11/27/2002 12/30/2002 $100 $100 $0 -  
2. 01002 Other 5144 D01 A 11/27/2002 12/30/2002 $100 $100 $0 -  
3. 01003 Other 5144 E01 11/27/2002 12/30/2002 $50 $50 $0 -  
4. 01004 Other 5144 F01 11/27/2002 12/30/2002 $150 $150 $0 -  
5. 02001 Serious 1534 A 11/27/2002 12/09/2002 $1,800 $1,800 $0 -  
6. 03001 Serious 1534 B 11/27/2002 12/09/2002 $1,800 $1,800 $0 -  

Investigation Summary

Investigation Nr: 201485042
Event: 08/06/2002
Employee Burns Forearms When Chemical Vapors Ignite

On August 6, 2002, Employee #1 was performing restoration efforts on a bathroom. As he was sitting on a toilet seat cover, applying Sunrez resin and acetone to a surface, Employee #1 turned on an ultraviolet halogen light. The resin and acetone released volatile vapors, ignited and Employee #1 sustained burns to his forearms. Employee #1 was transported to a medical facility, where he was treated and released. He returned to work the following day.

Keywords:burn, ventilation, flammable vapors, fire, forearm, construction, acetone, chemical vapor

Investigated Inspection
# Inspection Age Sex Degree Nature Occupation
1 301121182 Non Hospitalized injury Burn(Chemical) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close