Inspection Detail
Inspection: 301033387 - Scott Alarm
Inspection Information - Office: Jackson Area Office
Site Address:
Scott Alarm
104 Business Park Drive Suite H
Jackson, MS 39213
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:1731
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/03/1997
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 03/02/1998
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 101360535 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 2 | ||||
| Current Violations | 2 | 2 | ||||
| Initial Penalty | $0 | $0 | $0 | $3,250 | $0 | $3,250 |
| Current Penalty | $0 | $0 | $0 | $3,250 | $0 | $3,250 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 19040008 | 12/18/1997 | 12/23/1997 | $3,250 | $3,250 | $0 | - | ||
| 2. | 01002 | Other | 19100151 B | 12/18/1997 | 01/15/1998 | $0 | $0 | $0 | - |
Investigation Summary
An alarm installer and a trainee were installing a residential security alarm system. The two employees had completed all of the required drilling and were pulling component conductors into the attic. One of the conductors got snagged on a doorway. The installer sent the trainee from the attic to free the conductor. After the trainee left, the installer contacted ductwork for the heating system or the stovepipe. Both were energized by existing faulty wiring in the residence. The installer was electrocuted.
Keywords: DUCT, INSTALLING, ELECTRICAL, E GI VII, ELECTROCUTED, GROUND FAULT, EQUIPMENT GROUNDING, METAL PIPE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 301033387 | Fatality | Electric Shock | Occupation not reported |