Inspection Detail
Inspection: 300969730 - R.J.D. Exterior Designs, Inc.
Inspection Information - Office: Atlanta East Area Office
Site Address:
R.J.D. Exterior Designs, Inc.
345 Old Oxford Rd
Covington, GA 30209
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:1761
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/24/1997
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 08/14/1997
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361094063 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 1 | 4 | |||
| Current Violations | 3 | 1 | 4 | |||
| Initial Penalty | $6,300 | $0 | $0 | $5,000 | $0 | $11,300 |
| Current Penalty | $6,300 | $0 | $0 | $0 | $0 | $6,300 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19260020 B02 | 06/24/1997 | 07/21/1997 | $2,100 | $2,100 | $0 | - | ||
| 2. | 01002 | Serious | 19260451 F06 | 06/24/1997 | 07/14/1997 | $2,100 | $2,100 | $0 | - | ||
| 3. | 01003A | Serious | 19260451 F07 | 06/24/1997 | 07/14/1997 | $2,100 | $2,100 | $0 | - | ||
| 4. | 01003B | Serious | 19260021 B02 | 06/24/1997 | 07/14/1997 | $0 | $0 | $0 | - | ||
| 5. | 02001 | Other | 19040008 | 06/24/1997 | 07/14/1997 | $0 | $5,000 | $0 | I - Informal Settlement |
Investigation Summary
Two employees were dismantling an aluminum pump-jack scaffold. The aluminum poles were 7.3 meters long with a 3.7-meter extension, for a total length of 11.0 meters. The employees were dismantling the scaffold between a building and an overhead power line. The base of the pole they were moving was 1.2 meters away from the bottom of the building, and the power line was 4.6 meters from the building. One of the employees placed his foot at the base of the pole as a pivot, while the second employee walked the pole down. A gust of wind pushed the second employee backwards about two steps, allowing the pole to contact the 14.4-kilovolt power line. He was electrocuted.
Keywords: OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, METAL POLE, E C, SCAFFOLD
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 300969730 | Fatality | Electric Shock | Occupation not reported |
Translate