Inspection: 300956901 - Campbell & Associates, Inc
Inspection Information - Office: Birmingham Area Office
Site Address:
Campbell & Associates, Inc
5722 21st St South
Tuscaloosa, AL 35403
Mailing Address:
P.O. Box 2284, Tuscaloosa, AL 35403
Union Status: NonUnion
SIC:3441
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/03/1996
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 11/17/1999
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360674311 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 14 | 6 | 1 | 21 | ||
| Current Violations | 14 | 4 | 1 | 19 | ||
| Initial Penalty | $28,500 | $294,000 | $0 | $0 | $0 | $322,500 |
| Current Penalty | $10,000 | $90,000 | $0 | $0 | $0 | $100,000 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100132 D02 | 01/22/1997 | 02/18/1997 | $100 | $1,000 | $0 | 02/12/1997 | F - Formal Settlement | |
| 2. | 01002 | Serious | 19100146 D04 IV | 01/22/1997 | 01/27/1997 | $300 | $1,750 | $0 | 02/12/1997 | F - Formal Settlement | |
| 3. | 01003 | Serious | 19100146 G01 | 01/22/1997 | 01/27/1997 | $1,000 | $2,500 | $0 | 02/12/1997 | F - Formal Settlement | |
| 4. | 01004 | Serious | 19100146 I05 | 01/22/1997 | 01/27/1997 | $100 | $1,000 | $0 | 02/12/1997 | F - Formal Settlement | |
| 5. | 01005 | Serious | 19100146 J01 | 01/22/1997 | 01/27/1997 | $1,000 | $2,500 | $0 | 02/12/1997 | F - Formal Settlement | |
| 6. | 01006 | Serious | 19100146 K01 I | 01/22/1997 | 01/27/1997 | $1,000 | $2,500 | $0 | 02/12/1997 | F - Formal Settlement | |
| 7. | 01007 | Serious | 19100146 K01 III | 01/22/1997 | 01/27/1997 | $1,000 | $2,500 | $0 | 02/12/1997 | F - Formal Settlement | |
| 8. | 01008 | Serious | 19100146 K01 IV | 01/22/1997 | 01/27/1997 | $100 | $1,000 | $0 | 02/12/1997 | F - Formal Settlement | |
| 9. | 01009 | Serious | 19100147 C01 | 01/22/1997 | 02/18/1997 | $400 | $1,250 | $0 | 02/12/1997 | F - Formal Settlement | |
| 10. | 01010 | Serious | 19100307 B | 01/22/1997 | 01/27/1997 | $1,000 | $2,500 | $0 | 02/12/1997 | F - Formal Settlement | |
| 11. | 01011 | Serious | 19100307 B02 II | 01/22/1997 | 01/27/1997 | $1,000 | $2,500 | $0 | 02/12/1997 | F - Formal Settlement | |
| 12. | 01012 | Serious | 19100332 C | 01/22/1997 | 02/18/1997 | $1,000 | $2,500 | $0 | 02/12/1997 | F - Formal Settlement | |
| 13. | 01013 | Serious | 19100334 A02 I | 01/22/1997 | 01/27/1997 | $1,000 | $2,500 | $0 | 02/12/1997 | F - Formal Settlement | |
| 14. | 01014 | Serious | 19100304 F04 | 01/22/1997 | 01/27/1997 | $1,000 | $2,500 | $0 | 02/12/1997 | F - Formal Settlement | |
| 15. | 02001 | Willful | 19100146 C02 | 01/22/1997 | 01/27/1997 | $22,500 | $49,000 | $0 | 02/12/1997 | F - Formal Settlement | |
| 16. | 02002 | Willful | 19100146 D03 III | 01/22/1997 | 02/18/1997 | $0 | $49,000 | $0 | 02/12/1997 | F - Formal Settlement | Citation has been deleted. |
| 17. | 02003 | Willful | 19100146 D04 I | 01/22/1997 | 01/27/1997 | $0 | $49,000 | $0 | 02/12/1997 | F - Formal Settlement | Citation has been deleted. |
| 18. | 02004 | Willful | 19100146 D05 I | 01/22/1997 | 01/27/1997 | $22,500 | $49,000 | $0 | 02/12/1997 | F - Formal Settlement | |
| 19. | 02005 | Willful | 19100146 D05 II | 01/22/1997 | 01/27/1997 | $22,500 | $49,000 | $0 | 02/12/1997 | F - Formal Settlement | |
| 20. | 02006 | Willful | 19100146 J02 | 01/22/1997 | 01/27/1997 | $22,500 | $49,000 | $0 | 02/12/1997 | F - Formal Settlement | |
| 21. | 03001 | Other | 19100022 A02 | 01/22/1997 | 01/27/1997 | $0 | $0 | $0 | 02/12/1997 | F - Formal Settlement |
Investigation Summary
On August 5, 1996, Employee #1 was applying glue inside a vessel when an arc apparently caused a fire. He sustained burns and was transported to the hospital, where he died on August 20, 1996. A permit had not been issued for this work, nor was any testing of the tank performed. Employee #1 was wearing a supply air line respirator.
Keywords: BURN, VAPOR, FLAMMABLE LIQUID, FLAMMABLE VAPORS, GLUE, WORK RULES, FIRE, CHEMICAL VAPOR, TANK
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 300956901 | Fatality | Burn/Scald(Heat) | Occupation not reported |