Inspection: 300910767 - Synthetech Inc

Inspection Information - Office: Eugene

 

Inspection Nr: 300910767
Report ID: 1054194
Date Opened: 11/25/1997

Site Address:
Synthetech Inc
1290 Industrial Way Sw
Albany, OR 97321

Mailing Address:
Po Box 646, Albany, OR 97321

Union Status: NonUnion

SIC:8731

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 04/20/1998

Planning Guide: Health-Manufacturing

Emphasis:

Case Closed: 04/20/1998



Investigation Summary

Investigation Nr: 201200243
Event: 11/21/1997
EMPLOYEE BURNED FROM FLASH FIRE OF A CHEMICAL REACTION

At approximately 1:15 a.m. on November 21, 1997, Employee #1 was rinsing a reactor kettle after processing a chemical reaction for Amino Acid. He was looking into the kettle when the catalyst used in the reaction ignited and produced a flash fire. Employee #1 received second degree burns to his face, neck, shoulder, and right arm. He was taken to Albany Hospital and was later transferred to a burn center at a Portland Hospital.

Keywords: BURN, SHOULDER, FIRE, CHEMICAL REACTION, CHEMICAL BURN, NECK, ARM, FACE, CHEMICAL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300910767 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.