Powered by GoogleTranslate

Inspection Detail

Inspection: 300893682 - Imr Roofing, Inc.

Inspection Information - Office: San Francisco District Office

 

Inspection Nr: 300893682
Report ID: 0950611
Date Opened: 09/09/2003

Site Address:
Imr Roofing, Inc.
800 Innes Avenue
San Francisco, CA 94124

Mailing Address:
48 Chester Street, Daly City, CA 94014

Union Status: Union

SIC:1761

NAICS: 238160/Roofing Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/09/2003

Planning Guide: Safety-Construction

Emphasis: S:Construction (Cship)

Case Closed: 07/20/2005


Related Activity
Type Activity Nr Safety Health
Accident 361572886
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 2 6
Current Violations 4 2 6
Initial Penalty $26,325 $0 $0 $5,185 $0 $31,510
Current Penalty $19,170 $0 $0 $5,000 $0 $24,170
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 11/25/2003 12/01/2003 $5,000 $5,000 $0 -  
2. 01002 Other 1509 B 11/25/2003 12/28/2003 $0 $185 $0 A - Amendment  
3. 02001 Serious 2946 B02 11/25/2003 12/01/2003 $16,200 $16,200 $0 -  
4. 03001 Serious 1637 N01 11/25/2003 12/01/2003 $2,700 $3,375 $0 A - Amendment  
5. 04001 Serious 1644 A06 11/25/2003 12/01/2003 $0 $3,375 $0 A - Amendment  
6. 05001 Serious 1644 A07 11/25/2003 12/01/2003 $270 $3,375 $0 A - Amendment  

Investigation Summary

Investigation Nr: 201181807
Event: 09/05/2003
Employee injured in fall from scaffold after electric shock

At approximately 12:59 p.m. on September 5, 2003, Employee #1, a foreman at IMR Roofing, Inc., was standing on a metal scaffold platform while using a rope to hoist a 20 ft long metal gutter up to a roof. When the gutter reached the top of the scaffold's railing, he started to place it on the roof. Employee #1 was angling the gutter when it contacted a 12 kilovolt overhead power line. He sustained an electric shock that knocked him backward off the scaffold. Employee #1 fell approximately 10 ft to the third floor and sustained serious injuries. He was transported San Fransisco General Hospital, where he was admitted for treatment. The general contractor had moved the power line to put up the scaffold, which was erected between 7 ft and 9 ft away. The scaffold had no railing on the back and there was an approximately 2 ft gap between the scaffold and the building. In addition, the scaffold was not fully planked. The employer was cited for a violation of T8CCR 2946(b)(2), concerning proximity to overhead power lines.

Keywords: CLEARANCE, GUARDRAIL, OVERHEAD POWER LINE, WORK RULES, STRUCK AGAINST, CONSTRUCTION, ELECTRIC SHOCK, FALL, SCAFFOLD

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300893682 Hospitalized injury Burn(Chemical) Glaziers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close