Inspection Detail
Inspection: 300874336 - Woodridge Productions Inc Dba Justified
Inspection Information - Office: Los Angeles District Office
Site Address:
Woodridge Productions Inc Dba Justified
25135 Anza Dr., Stage 6
Santa Clarita, CA 91355
Mailing Address:
, , 00000
Union Status: Union
SIC:7812
NAICS: 512110/Motion Picture and Video Production
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/22/2012
Emphasis:
Case Closed: 03/22/2012
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 102758703 |
Investigation Summary
On October 20, 2011, Employee #1, with a film production company, was using an Airy pneumatic nail gun (Model Number CDL C332) to fasten a doorstop to a door casing for a prop. The stop area was slightly above her head. The nail gun had a safety latch and an actuation trigger. The gun was reportedly difficult to pick up without depressing the safety latch. While Employee #1 was moving her finger off the safety, another finger hit the trigger. A nail punctured her forearm. Employee #1 was initially treated at a local clinic and released. Two days later, she was admitted to a hospital for surgery.
Keywords: PORTABLE POWER TOOL, NAIL, FOREARM, AIR HOSE, ARM, PUNCTURE
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 300874336 | Hospitalized injury | Puncture | Patternmakers and model makers, wood |