Inspection Detail
Inspection: 300872850 - Binder Tec
Inspection Information - Office: Los Angeles District Office
Site Address:
Binder Tec
12703 Cerise Ave.
Hawthorne, CA 90250
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:2671
NAICS: 322221/Coated and Laminated Packaging Paper and Plastics Film Manufacturing
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/09/2010
Emphasis:
Case Closed: 07/25/2011
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 102578341 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 8 | 9 | |||
Current Violations | 1 | 8 | 9 | |||
Initial Penalty | $3,150 | $0 | $0 | $2,170 | $0 | $5,320 |
Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 461 C | 03/09/2010 | 03/12/2010 | $0 | $435 | $0 | 05/18/2010 | J - ALJ Decision | |
2. | 01002 | Other | 3664 A | 03/09/2010 | 04/23/2010 | $0 | $175 | $0 | 05/18/2010 | J - ALJ Decision | |
3. | 01003 | Other | 3203 A | 03/09/2010 | 03/12/2010 | $0 | $260 | $0 | 05/18/2010 | J - ALJ Decision | |
4. | 01004 | Other | 3273 A | 03/09/2010 | 03/12/2010 | $0 | $260 | $0 | 05/18/2010 | J - ALJ Decision | |
5. | 01005 | Other | 3400 C | 03/09/2010 | 04/23/2010 | $0 | $260 | $0 | 05/18/2010 | J - ALJ Decision | |
6. | 01006 | Other | 3668 A01 | 03/09/2010 | 04/23/2010 | $0 | $260 | $0 | 05/18/2010 | J - ALJ Decision | |
7. | 01007 | Other | 4051 A | 03/09/2010 | 04/23/2010 | $0 | $260 | $0 | 05/18/2010 | J - ALJ Decision | |
8. | 01008 | Other | 4207 A01 | 03/09/2010 | 04/23/2010 | $0 | $260 | $0 | 05/18/2010 | J - ALJ Decision | |
9. | 02001 | Serious | 4002 A | 02/09/2010 | 03/29/2010 | $0 | $3,150 | $0 | 05/18/2010 | J - ALJ Decision |
Investigation Summary
At approximately 9:15 a.m. on January 4, 2010, two workers of Binder Tec, a packaging company, were burned when one of them tried to jump-start a forklift truck with a -portable battery pack. The workers were taken to Sentinels Hospital, and were released after a couple of hours. An investigation revealed that the accident may have been caused by a spark generated near the leaky tank on the propane-powered forklift.
Keywords: BATTERY, BURN, LEAK, JUMP START, INDUSTRIAL TRUCK, PROPANE, SPARK, TANK
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 300872850 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported | ||
2 | 300872850 | Hospitalized injury | Burn(Chemical) | Occupation not reported |