Powered by GoogleTranslate

Inspection Detail

Inspection: 300870755 - 911 Restoration Enterprises Inc

Inspection Information - Office: Los Angeles District Office

 

Inspection Nr: 300870755
Report ID: 0950641
Date Opened: 10/06/2009

Site Address:
911 Restoration Enterprises Inc
1200 S. Corning St. #103
Los Angeles, CA 90035

Mailing Address:
7721 Densmore Ave., Van Nuys, CA 91406

Union Status: NonUnion

SIC:1799

NAICS: 238910/Site Preparation Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/27/2009

Emphasis: S:Construction (Cship)

Case Closed: 12/15/2012


Related Activity
Type Activity Nr Safety Health
Accident 102577442
Accident 102577467
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 4 7
Current Violations 2 5 7
Initial Penalty $18,670 $0 $0 $1,000 $0 $19,670
Current Penalty $11,700 $0 $0 $250 $0 $11,950
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 1509 A 03/18/2010 04/20/2010 $50 $165 $0 04/12/2010 F - Formal Settlement  
2. 01002 Other 1512 B 03/18/2010 04/20/2010 $50 $335 $0 04/12/2010 F - Formal Settlement  
3. 01003 Other 3382 A 03/18/2010 04/20/2010 $50 $165 $0 04/12/2010 F - Formal Settlement  
4. 01004 Other 5194 H02 00E 03/18/2010 04/20/2010 $50 $335 $0 04/12/2010 F - Formal Settlement  
5. 02001 Serious 23400002 B 03/18/2010 04/05/2010 $900 $3,035 $0 04/12/2010 F - Formal Settlement  
6. 03001 Other 23950051 A01 03/18/2010 04/05/2010 $50 $3,035 $0 04/12/2010 F - Formal Settlement  
7. 04001 Serious 5416 C 03/18/2010 04/05/2010 $10,800 $12,600 $0 04/12/2010 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202541322
Event: 09/29/2009
Two Employees Are Burned When Flammable Vapors Explode

On September 29, 2009, Employees #1 and #2, who were employed by a restoration services company, were working in an apartment unit, on the second floor of an inhabited, four-story multi-unit residential building. The workers had been at the site on two previous occasions to expose framing members by removing drywall and then to enclosed the subject area with plastic sheeting. Because test results from an independent testing lab showed that mold was still present, Employees #1 and #2 returned to the apartment unit a third time to encapsulate the mold. Employees #1 and #2 were spraying Kilz(R) Original Aerosol to encapsulate visible mold that was on the framing members of an interior partition wall of the apartment unit, while inside the plastic-enclosed containment area. The homeowner was in the kitchen area of the apartment. Employees #1 and #2 exhausted four and one-half, 13-ounce-sized cans of the flammable aerosol within the containment area, which measured 41 inches deep by 8 feet long by 8 feet, 10 inches high. They then plugged into an electrical outlet an OmniAire 1000V HEPA air filtration machine, which was also inside the containment area. An explosion and fire occurred, when an ignition source was introduced inside the containment area where flammable vapors were concentrated. Employees #1 and #2 sustained serious burns (second and third degree) to their upper bodies and faces. They required inpatient hospitalization for more than 24 hours. According to the manufacturer, OmniAire 1000V was an air filtering machine designed for filtering particulates and providing negative air pressure for asbestos abatement. The machine was listed as meeting requirements for UL (Underwriters Laboratories) Standard UL507 for Safety for Electric Fans. The listing did not include use in hazardous atmospheres, where flammable vapors were present. The machine had a variable speed controller and Emerson, open-frame type fan motor. The investigation found that the employer's IIPP (Injury and Illness Prevention Program) lacked several required elements and that the workers were not trained on the physical or health hazards of the Kilz(R) Original Aerosol. Further, the improper use of listed equipment in a hazardous atmosphere caused the explosion and fire. The employer was issued citations accordingly.

Keywords: BURN, ENCLOSED SPACE, FAN, FLAMMABLE LIQUID, FLAMMABLE VAPORS, FIRE, CONSTRUCTION, EXPLOSION, AIR CONTAMINATION, HIGH TEMPERATURE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300870755 Hospitalized injury Burn/Scald(Heat) Technicians, n.e.c.
2 300870755 Hospitalized injury Burn/Scald(Heat) Technicians, n.e.c.
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.