Inspection Detail
Inspection: 300866621 - See'S Candy Shops Inc
Inspection Information - Office: Los Angeles District Office
Site Address:
See'S Candy Shops Inc
3423 S. La Cienega Blvd.
Los Angeles, CA 90016
Mailing Address:
, , 00000
Union Status: Union
SIC:2066
NAICS: 311320/Chocolate and Confectionery Manufacturing from Cacao Beans
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/28/2004
Emphasis:
Case Closed: 07/06/2006
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 101160794 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 4 | 5 | |||
| Current Violations | 1 | 4 | 5 | |||
| Initial Penalty | $6,750 | $0 | $0 | $11,475 | $0 | $18,225 |
| Current Penalty | $4,050 | $0 | $0 | $1,800 | $0 | $5,850 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3314 H02 | 06/28/2004 | 07/16/2004 | $150 | $420 | $0 | 07/14/2004 | F - Formal Settlement | |
| 2. | 01002 | Other | 3203 A07 | 06/28/2004 | 07/16/2004 | $600 | $935 | $0 | 07/14/2004 | F - Formal Settlement | |
| 3. | 02001 | Other | 3314 F | 06/28/2004 | 07/16/2004 | $450 | $5,060 | $0 | 07/14/2004 | F - Formal Settlement | |
| 4. | 03001 | Other | 3328 E | 06/28/2004 | 07/16/2004 | $600 | $5,060 | $0 | 07/14/2004 | F - Formal Settlement | |
| 5. | 04001 | Serious | 3214 B | 06/28/2004 | 07/16/2004 | $4,050 | $6,750 | $0 | 07/14/2004 | F - Formal Settlement |
Investigation Summary
On February 26, 2004, Employee #1 was employed by See's Candy since 1989 as a Porte; Employee #1 was steam cooking which cooked a mixture of ingredients to make candy. Employee #1 went to clean the steamer cooker k32 she noticed that the team did not come into the cooker as needed, to clean the interior of the cooker after she turned on the switch, as result the bursting steam burned her lower body as she sustained severe steam burn, to her lower body .She was transported to Torrance Memorial medical Center for Emergency treatment.
Keywords: BURN, REPAIR, CLEANING, STEAM, VALVE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 300866621 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported |
Translate