Powered by GoogleTranslate

Inspection Detail

Inspection: 300864774 - Discount Ceramic Tiles Of Riverside

Inspection Information - Office: San Bernardino District Office

 

Inspection Nr: 300864774
Report ID: 0950633
Date Opened: 02/06/2004

Site Address:
Discount Ceramic Tiles Of Riverside
22322 Sioux Road
Apple Valley, CA 92308

Mailing Address:
570 E La Cadena Suite 1e, Riverside, CA 92501

Union Status: NonUnion

SIC:1743

NAICS: 238340/Tile and Terrazzo Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 08/05/2004

Emphasis: S:Construction (Cship)

Case Closed: 07/21/2008


Related Activity
Type Activity Nr Safety Health
Accident 101154037
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 1 4
Current Violations 3 1 4
Initial Penalty $33,250 $0 $0 $5,000 $0 $38,250
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 08/05/2004 08/13/2004 $0 $5,000 $0 08/30/2004 J - ALJ Decision  
2. 02001 Serious 1533 A 08/05/2004 08/13/2004 $0 $13,500 $0 08/30/2004 J - ALJ Decision  
3. 03001 Serious 5155 E01 08/05/2004 08/13/2004 $0 $13,000 $0 08/30/2004 J - ALJ Decision  
4. 04001 Serious 1509 A 08/05/2004 08/13/2004 $0 $6,750 $0 08/30/2004 J - ALJ Decision  

Investigation Summary

Investigation Nr: 201159159
Event: 02/05/2004
Two Employees Are Asphyxiated by Carbon Monoxide

Sometime in the evening on February 5, 2004, Employees #1 and #2 were laying ceramic tile within a closed single family structure under construction. They were utilizing a gasoline-powered generator, Honda, Model Number EB3000, Serial Number GCAE-1932433, located in the garage to provide electricity for the electric powered mixing and cutting devices, which were used to affect the ceramic tile laying operation. Employees #1 and #2 were operating a gasoline-powered electric generator within a closed structure that lacked any exhaust ventilation devices. Since all doors and windows were closed, Employees #1 and #2 were exposed to a lethal concentration of carbon monoxide gas. They were asphyxiated. Employees #1 and #2 were found dead the following morning in the master bathroom of the single floor residence.

Keywords: EXHAUST SYSTEM, ASPHYXIATED, INHALATION, GAS, GASOLINE, CARBON MONOXIDE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300864774 Fatality Other Tile setters, hard and soft
2 300864774 Fatality Other Tile setters, hard and soft
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close