Inspection Detail
Inspection: 300863065 - Tibban Tanks, Inc
Inspection Information - Office: San Bernardino District Office
Site Address:
Tibban Tanks, Inc
17178 Raccoon Ave
Adelanto, CA 92301
Mailing Address:
P.O. Box 367, Adelanto, CA 92301
Union Status: NonUnion
SIC:3443
NAICS: 332420/Metal Tank (Heavy Gauge) Manufacturing
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 02/04/2004
Emphasis:
Case Closed: 08/07/2004
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 101151389 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 8 | 11 | |||
| Current Violations | 3 | 8 | 11 | |||
| Initial Penalty | $15,520 | $0 | $0 | $6,390 | $0 | $21,910 |
| Current Penalty | $15,520 | $0 | $0 | $6,390 | $0 | $21,910 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 342 A | 02/04/2004 | 03/08/2004 | $5,000 | $5,000 | $0 | - | ||
| 2. | 01002 | Other | 461 C | 02/04/2004 | 02/23/2004 | $175 | $175 | $0 | - | ||
| 3. | 01003 | Other | 3203 B01 | 02/04/2004 | 03/08/2004 | $130 | $130 | $0 | - | ||
| 4. | 01004 | Other | 3203 A05 | 02/04/2004 | 02/23/2004 | $130 | $130 | $0 | - | ||
| 5. | 01005 | Other | 3328 E | 02/04/2004 | 02/23/2004 | $260 | $260 | $0 | - | ||
| 6. | 01006 | Other | 3668 F | 02/04/2004 | 03/08/2004 | $175 | $175 | $0 | - | ||
| 7. | 01007 | Other | 5144 C01 | 02/04/2004 | 02/23/2004 | $260 | $260 | $0 | - | ||
| 8. | 01008 | Other | 5194 E01 | 02/04/2004 | 03/08/2004 | $260 | $260 | $0 | - | ||
| 9. | 02001 | Serious | 25400002 A | 02/04/2004 | 02/13/2004 | $2,360 | $2,360 | $0 | - | ||
| 10. | 03001 | Serious | 3210 A | 02/04/2004 | 02/13/2004 | $2,360 | $2,360 | $0 | - | ||
| 11. | 04001 | Serious | 5157 D03 | 02/04/2004 | 02/13/2004 | $10,800 | $10,800 | $0 | - |
Investigation Summary
On August 4, 2003, Employee #1 sustained burns when an explosion occurred while he was spray painting the interior of a pressure tank, a confined space, being fabricated on site. The employer fabricates pressure and water tanks. Employee #1 is an employee of the employer and is a foreman. On the day of injury, Employee #1 was inside a pressure tank. The one opening to the tank measured 16-inches wide and 12-inches high. Employee #1 was conducting spray painting operation with a two-part paint component. Inside the tank was a work lamp that did not have a cover over the bulb. Employee #1 was wearing a continuous-flow respirator. An explosion occurred while Employee #1 was spray painting inside the tank. Employee #1 sustained second and third-degree burns to approximately 30 percent of his body and was hospitalized.
Keywords: BURN, CONFINED SPACE, SPRAY PAINTING, EXPLOSION, TANK, RESPIRATOR
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 300863065 | Hospitalized injury | Burn/Scald(Heat) | Supervisors, production occupations |
Translate