Powered by GoogleTranslate

Inspection Detail

Inspection: 300862927 - Brithinee Electric

Inspection Information - Office: San Bernardino District Office

 

Inspection Nr: 300862927
Report ID: 0950633
Date Opened: 07/22/2003

Site Address:
Brithinee Electric
620 S Rancho Ave
Colton, CA 92324

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:7629

NAICS: 811412/Appliance Repair and Maintenance


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/24/2003

Emphasis:

Case Closed: 04/13/2010


Related Activity
Type Activity Nr Safety Health
Accident 362459646
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 3 4
Current Violations 4 4
Initial Penalty $14,400 $0 $0 $545 $0 $14,945
Current Penalty $0 $0 $0 $1,370 $0 $1,370
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 23400022 A 12/24/2003 01/05/2004 $135 $135 $0 01/22/2004 F - Formal Settlement  
2. 01002 Other 3328 D 12/24/2003 01/05/2004 $135 $135 $0 01/22/2004 F - Formal Settlement  
3. 01003 Other 3328 G 12/24/2003 01/05/2004 $275 $275 $0 01/22/2004 F - Formal Settlement  
4. 02001 Other 3328 A 12/24/2003 01/05/2004 $825 $14,400 $0 01/22/2004 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201157807
Event: 07/07/2003
Employee injures fingers while operating hydraulic press

At approximately 2:30 p.m. on July 07, 2003, Employee #1, operating a Poulan hydraulic horizontal press, Model Number P-200, Serial Number 3034, was removing a coupling from a generator. He pushed the button with his left hand to build up pressure to approximately 8,000 psi and noticed that the coupling did not move. Arm pullers were used on the left and right side to hold the coupling in place so the shaft could be pushed to remove the coupling. The employee leaned over to check the alignment and placed his right hand on the left side arm puller. The left side arm puller broke off and the right side arm puller moved towards the face of the generator. The employee's right hand got caught between the arm puller and the face of the generator. He received multiple fractures on his right middle and ring finger and was hospitalized.

Keywords: FRACTURE, CAUGHT BETWEEN, HYDRAULIC PRESS, PRESS OPERATOR, HAND, PRESS

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300862927 Hospitalized injury Fracture Supervisors, mechanics and repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.