Inspection Detail
Inspection: 300861226 - Tyler Self Storage
Inspection Information - Office: San Bernardino District Office
Site Address:
Tyler Self Storage
10335 Indiana Ave
Riverside, CA 92503
Mailing Address:
P.O. Box 507, Santa Ana, CA 92702
Union Status: NonUnion
SIC:4225
NAICS: 531130/Lessors of Miniwarehouses and Self-Storage Units
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/09/2003
Emphasis:
Case Closed: 03/10/2016
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362457616 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 3 | 4 | |||
| Current Violations | 1 | 3 | 4 | |||
| Initial Penalty | $2,925 | $0 | $0 | $975 | $0 | $3,900 |
| Current Penalty | $2,250 | $0 | $0 | $0 | $0 | $2,250 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3203 A04 | 07/09/2003 | 08/11/2003 | $0 | $325 | $0 | I - Informal Settlement | ||
| 2. | 01002 | Other | 3328 G | 07/09/2003 | 08/11/2003 | $0 | $325 | $0 | I - Informal Settlement | ||
| 3. | 01003 | Other | 3556 A | 07/09/2003 | 08/11/2003 | $0 | $325 | $0 | I - Informal Settlement | ||
| 4. | 02001 | Serious | 23950051 A01 | 07/09/2003 | 07/28/2003 | $2,250 | $2,925 | $0 | I - Informal Settlement |
Investigation Summary
An employee of a self-storage facility was installing outdoor floodlights. Standing on a 6.1-meter-long fiberglass extension ladder with aluminum steps, he drilled a hole in a brick wall. (The hole was for electrical conduit.) After drilling the hole, he draped the electric drill's power supply cord over one of the ladder steps. As he descended the ladder, He received an electric shock, let go of the ladder, and fell to the metal surface on which the ladder was resting. The employee sustained a fracture to his left proximal tibia and required surgery for the insertion of a plate in his left knee. He remained hospitalized for 4 days. An electrical test of the drill revealed an open ground, and the inspection found that the receptacle to which the drill was connected was equipped with a ground-fault circuit interrupter that did not open the circuit.
Keywords: FRACTURE, ELECTRICAL, E GI VII, GROUND FAULT, EQUIPMENT GROUNDING, ELECTRIC SHOCK, FALL, ELECTRIC DRILL
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 300861226 | Hospitalized injury | Fracture | Helpers, mechanics and repairers |
Translate