Powered by GoogleTranslate

Inspection Detail

Inspection: 300848686 - Aluminum Precision Products

Inspection Information - Office: Santa Ana District Office

 

Inspection Nr: 300848686
Report ID: 0950631
Date Opened: 10/20/2000

Site Address:
Aluminum Precision Products
3333 W Warner Ave
Santa Ana, CA 92704

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3555

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/20/2000

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 11/01/2001


Related Activity
Type Activity Nr Safety Health
Accident 362395782
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $0 $0 $0 $150 $0 $150
Current Penalty $0 $0 $0 $150 $0 $150
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A07 B 12/06/2000 01/08/2001 $150 $150 $0 -  

Investigation Summary

Investigation Nr: 201141777
Event: 06/05/2000
Employees burned by hot oil spray

At approximately 11:15 p.m. on July 5, 2000, Employees #1 and #2 were operating the #6 hydraulic press when a nipple fitting broke, releasing a stream of hot oil that flowed to the base of the press. The oil then went through the press and ignited, spraying the flaming oil onto Employees #1 and #2. They were hospitalized with burns over multiple parts of their bodies.

Keywords: BURN, LEAK, FLAMMABLE LIQUID, FIRE, HYDRAULIC FLUID, EQUIPMENT FAILURE, COMBUSTIBLE LIQUID, SPILL, HYDRAULIC PRESS, PRESS OPERATOR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300848686 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 300848686 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.