Powered by GoogleTranslate

Inspection Detail

Inspection: 300848512 - Priority Building Services

Inspection Information - Office: Santa Ana District Office

 

Inspection Nr: 300848512
Report ID: 0950631
Date Opened: 09/29/2000

Site Address:
Priority Building Services
1732 Reynolds
Irvine, CA 92614

Mailing Address:
555 W Lambert #K, Brea, CA 92821

Union Status: NonUnion

SIC:7349

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/08/2000

Emphasis:

Case Closed: 09/19/2006


Related Activity
Type Activity Nr Safety Health
Accident 362396384
Accident 362396806
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 3 5
Current Violations 1 4 5
Initial Penalty $15,750 $70,000 $0 $870 $0 $86,620
Current Penalty $0 $49,000 $0 $1,510 $0 $50,510
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 23400021 12/15/2000 01/17/2001 $260 $260 $0 02/02/2001 W - Empr Withdrew  
2. 01002 Other 3203 A 12/15/2000 01/17/2001 $0 $260 $0 02/02/2001 F - Formal Settlement  
3. 01003 Other 342 A 12/15/2000 12/20/2000 $350 $350 $0 02/02/2001 W - Empr Withdrew  
4. 02001 Other 23400023 12/15/2000 01/03/2001 $900 $15,750 $0 02/02/2001 F - Formal Settlement  
5. 03001 Willful 5417 B 12/15/2000 12/20/2000 $49,000 $70,000 $0 02/02/2001 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201141694
Event: 09/27/2000
Employee Burned When Vapors are Ignited By Buffing Machine

Two employees were removing an adhesive from work space floors with a buffing machine. A gasoline and chemical mixture was used to remove the adhesive, although the buffer had a clearly marked warning sign prohibiting its use with flammable or combustible liquids. After several hours of operation the flammable vapors ignited causing a fire. One employee was hospitalized with second and third degree burns over 90 percent of his body.

Keywords: BURN, VAPOR, FLAMMABLE LIQUID, FLAMMABLE VAPORS, FIRE, COMBUSTIBLE LIQUID, GASOLINE, CHEMICAL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300848512 Hospitalized injury Burn/Scald(Heat) Janitors and cleaners
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close