Inspection Detail
Inspection: 300844354 - Romic Environmental Technologies
Inspection Information - Office: Ca Foster City District Office
Site Address:
Romic Environmental Technologies
2081 Bay Road
East Palo Alto, CA 94303
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:4953
NAICS: 562211/Hazardous Waste Treatment and Disposal
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/21/2006
Emphasis:
Case Closed: 12/31/2006
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 101128338 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 3 | 1 | 4 | |||
Current Violations | 3 | 1 | 4 | |||
Initial Penalty | $31,385 | $0 | $0 | $635 | $0 | $32,020 |
Current Penalty | $18,760 | $0 | $0 | $635 | $0 | $19,395 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 5189 N | 07/24/2006 | 08/26/2006 | $635 | $635 | $0 | 09/08/2006 | F - Formal Settlement | |
2. | 02001 | Serious | 5166 B | 07/24/2006 | 07/27/2006 | $18,000 | $18,000 | $0 | 09/08/2006 | F - Formal Settlement | |
3. | 03001 | Serious | 5189 K02 | 07/24/2006 | 07/27/2006 | $380 | $7,650 | $0 | 09/08/2006 | F - Formal Settlement | |
4. | 04001 | Serious | 5561 B | 07/24/2006 | 07/27/2006 | $380 | $5,735 | $0 | 09/08/2006 | F - Formal Settlement |
Investigation Summary
On March 2, 2006, Employee #1, a welder, was torch cutting on top of a 12,000 gallon carbon-steel tank in a hazardous waste treatment, storage, and recycling facility. The tank, which had a cone bottom and was about 28.5 feet above the ground, had previously held solvent contaminated wastewater. An Industrial Scientific Corporation multi-gas monitoring instrument, Model Number 140, Serial Number 0312193-005, equipped with a sampling pump, Serial Number 05120XW-025, and 6.5-foot tubing, entering the tank from an 8-inch top hatch, was used to monitor the atmosphere inside the tank. As Employee #1 was kneeling next to the top hatch of the tank, on the walkway above the tank, torch cutting through the top of the tank, a fire occurred. Flames came out of the top hatch and caught his clothes on fire. Employee #1 was hospitalized approximately six hours later, where he was treated for second and third degree burns on his buttock and perineum area. Employee #1 was wearing a personal fall arrest system to include a body harness and shock absorbing lanyard, which allowed him to reach outside the guarded walkway. The accident investigation revealed that the accident was caused by inadequate preparation of the tank for hot work. Although the tank had been steam cleaned prior to the welding operation, the tank was neither isolated nor purged. Additionally, there was insufficient monitoring of the tank atmosphere. The employer was issued two serious violations, prohibiting their engagement in activities requiring the use of direct air monitoring equipment, as well as welding operations.
Keywords:burn, flammable vapors, buttocks, fire, welder, gas, torch, tank, cutting and burning
# | Inspection | Age | Sex | Degree | Nature | Occupation |
---|---|---|---|---|---|---|
1 | 300844354 | Hospitalized injury | Burn/Scald(Heat) | Welders and cutters |