Inspection Detail
Inspection: 300841038 - C.P.I./Eimac
Inspection Information - Office: Foster City District Office
Site Address:
C.P.I./Eimac
301 Industrial Road
San Carlos, CA 94070
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3671
NAICS: 334411/Electron Tube Manufacturing
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/13/2004
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 06/30/2005
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 101125664 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $2,700 | $0 | $0 | $0 | $0 | $2,700 |
| Current Penalty | $2,700 | $0 | $0 | $0 | $0 | $2,700 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 2717 | 10/14/2004 | 10/19/2004 | $2,700 | $2,700 | $0 | - |
Investigation Summary
At approximately 10:00 a.m. on April 15, 2004, Employee #1 was working in an electronic equipment test cell, when he contacted an open electrical panel that carried 30 KVs. Employee #1 was electrocuted, receiving burns on his hand. Employee #1 was hospitalized and treated for his injury.
Keywords: BURN, PPE, GUARD, ELECTROCUTED, LOCKOUT, ELECTRIC SHOCK, INATTENTION
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 300841038 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported |
Translate