Inspection Detail
Inspection: 300835808 - Tyco Thermal Controls
Inspection Information - Office: Foster City District Office
Site Address:
Tyco Thermal Controls
2501 Bay Road
Redwood City, CA 94063
Mailing Address:
2555 Bay Road, Redwood City, CA 94063
Union Status: NonUnion
SIC:3315
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/24/2001
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 12/31/2003
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 101122000 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 2 | ||||
| Current Violations | 2 | 2 | ||||
| Initial Penalty | $20,700 | $0 | $0 | $0 | $0 | $20,700 |
| Current Penalty | $20,700 | $0 | $0 | $0 | $0 | $20,700 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 3308 | 10/24/2001 | 11/26/2001 | $2,700 | $2,700 | $0 | 01/16/2002 | W - Empr Withdrew | |
| 2. | 02001 | Serious | 4002 A | 10/24/2001 | 11/26/2001 | $18,000 | $18,000 | $0 | 01/16/2002 | W - Empr Withdrew |
Investigation Summary
At approximately 11:55 a.m. on June 7, 2001, Employee #1 was operating an insulation extruder machine. As he knotted the tail ends of two moving braided conductors, just before they entered the extruder, his finger became entangled in the knot and was pulled into the opening and amputated. His injury required hospitalization.
Keywords: ELEC INSULATION, AMPUTATED, FINGER, ELECTRIC CONDUCTOR, ENTANGLED, NIP POINT
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 300835808 | Hospitalized injury | Amputation | Occupation not reported |
Translate