Powered by GoogleTranslate

Inspection Detail

Inspection: 300833951 - Norman Wireline Services, Inc.

Inspection Information - Office: Van Nuys District Office

 

Inspection Nr: 300833951
Report ID: 0950643
Date Opened: 04/05/2006

Site Address:
Norman Wireline Services, Inc.
600 Shell Rd.
Ventura, CA 93001

Mailing Address:
1301 James Rd., Bakersfield, CA 93308

Union Status: NonUnion

SIC:1389

NAICS: 213112/Support Activities for Oil and Gas Operations


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/17/2006

Emphasis:

Case Closed: 12/28/2008


Related Activity
Type Activity Nr Safety Health
Accident 101112191
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 2 3
Current Violations 2 2
Initial Penalty $12,600 $0 $0 $560 $0 $13,160
Current Penalty $0 $0 $0 $585 $0 $585
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A05 07/17/2006 08/04/2006 $0 $110 $0 08/15/2006 F - Formal Settlement Citation has been deleted.
2. 01002 Other 3384 B 07/17/2006 08/04/2006 $250 $450 $0 08/15/2006 F - Formal Settlement  
3. 02001 Other 4002 A 07/17/2006 07/27/2006 $335 $12,600 $0 08/15/2006 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202463071
Event: 01/17/2006
Employee's Finger Is Amputated by Wire Rope

At approximately 11:00 a.m. on January 17, 2006, Employee #1 a blaster with a small surface blasting company, that also performs down-hole recovery of trapped drill pipe, was working with a coworker, who was operating the draw-works from inside a 2-ton wireline truck. After locating a trapped section of drill pipe, they began the process of "zeroing" a chemical cutting tool. Employee #1 was located between the well bore and the lower sheave. The wireline ran from the wireline truck to the lower sheave then up to the upper sheave mounted on the sand line of the work-over rig then down towards the well bore. The lower sheave was attached to the blow-out preventer with a wire rope sling. Employee #1 observed the coworker retract the wireline. When the wire line halted, Employee #1 believed that it had seized. He then grabbed the wire rope to free the line. The coworker had not completed the zeroing process and retracted the line again. Employee #1's gloved left hand then became caught and pulled into the sheave. His hand was pinched between the wire rope and the lower sheave guide, and his fourth finger was amputated. The unguarded sheave was the cause of the accident.

Keywords: AMPUTATED, WIRE ROPE, FINGER, GLOVE, CAUGHT BETWEEN, PULLEY, HAND, UNGUARDED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300833951 Non Hospitalized injury Amputation Hoist and winch operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close