Inspection Detail
Inspection: 300829850 - Key Energy Services - California, Inc
Inspection Information - Office: Van Nuys District Office
Site Address:
Key Energy Services - California, Inc
Highway 33 Between Hwy. 46 & Lokern Rd.
Bakersfield, CA 93308
Mailing Address:
18835 Highway 65, Bakersfield, CA 93308
Union Status: NonUnion
SIC:1389
NAICS: 213112/Support Activities for Oil and Gas Operations
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/04/2005
Emphasis:
Case Closed: 11/04/2005
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361395023 |
Investigation Summary
At approximately 12:30 p.m. on May 3, 2005, an employee, a well puller, and the crew were involved in a pump change. The employee was performing a regularly assigned task of repairing the bridle on a beam pumping unit in the attempt to complete repairs on the unit. The employee was near the end of the replacement of the pump and was lowering the polish rod when his left hand was caught between the bottom of the carrier bar and the top of the polish rod clamp. The weight of the polish rod on the carrier bar crushed the employee's left ring finger. The employee was working with the derrickman at the time. The Tool pusher was not in the area at the time of the accident. The employee sustained an amputation of the tip of the left ring finger due to being crushed between the carrier bar and polish rod clamp on top of the stuffing box of a beam pumping unit. He was transported and treated at Valley Industrial Medical Group and released.
Keywords: FINGER, WELL, CAUGHT BETWEEN, CRUSHED, OIL RIG
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 300829850 | Non Hospitalized injury | Amputation | Drillers, oil well |