Powered by GoogleTranslate

Inspection Detail

Inspection: 300829728 - Certis Usa

Inspection Information - Office: Van Nuys District Office

 

Inspection Nr: 300829728
Report ID: 0950643
Date Opened: 05/25/2005

Site Address:
Certis Usa
720 5th St.
Wasco, CA 93280

Mailing Address:
, , 00000

Union Status: Union

SIC:2879

NAICS: 325320/Pesticide and Other Agricultural Chemical Manufacturing


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/25/2005

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 07/01/2006


Related Activity
Type Activity Nr Safety Health
Accident 362526501
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $0 $0 $0 $5,550 $0 $5,550
Current Penalty $0 $0 $0 $5,550 $0 $5,550
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 10/27/2005 11/01/2005 $5,000 $5,000 $0 -  
2. 01002 Other 3203 A07 C 10/27/2005 11/29/2005 $550 $550 $0 -  

Investigation Summary

Investigation Nr: 201119799
Event: 05/03/2005
Employee Is Burned When Splashed Accidentally by Hot Water

On May 3, 2005, an employee was instructed by his supervisor to unplug the tamol tank which contained hot water at 90 degree Fahrenheit. The employee was suppose to drain the hot water with a pump first and then unplug the valve. The employee went underneath the tank and placed compress air in the valve to unplug it. He indicated that he accidently opened the airline with his tools and the compress air forced the hot water out of tank. The hot water splashed on the employee's back, right arm and shoulder, left wrist, back of neck, and right ear. The employee went to the locker room, where his supervisor provided first aid and then took him to Willard B. Christiansen M.D. Inc. The employee was then taken to Sherman Oak Burn Center Hospital. He was diagnosed with first, second, and third degree burns on his arm, face, back. He was in the hospital for more than 24 hrs.

Keywords: BURN, COMPRESSED AIR, EAR, BACK, ARM, FACE, HOT WATER, WRIST

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300829728 Hospitalized injury Burn/Scald(Heat) Miscellaneous plant and system operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.