Powered by GoogleTranslate

Inspection Detail

Inspection: 300829553 - Pharmavite

Inspection Information - Office: Van Nuys District Office

 

Inspection Nr: 300829553
Report ID: 0950643
Date Opened: 05/03/2005

Site Address:
Pharmavite
1150 Aviation Place
San Fernanado, CA 91342

Mailing Address:
P.O. Box 9606, Mission Hills, CA 91346

Union Status: NonUnion

SIC:2834

NAICS: 325412/Pharmaceutical Preparation Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/01/2005

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 08/14/2008


Related Activity
Type Activity Nr Safety Health
Accident 361394901
Accident 361395825
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 2 6
Current Violations 4 2 6
Initial Penalty $44,500 $0 $0 $370 $0 $44,870
Current Penalty $19,685 $0 $0 $370 $0 $20,055
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 25000010 A 10/31/2005 11/18/2005 $185 $185 $0 11/15/2005 F - Formal Settlement  
2. 01002 Other 5143 A05 11/02/2005 12/07/2005 $185 $185 $0 11/15/2005 F - Formal Settlement  
3. 02001 Serious 5174 A 11/01/2005 12/06/2005 $18,000 $25,000 $0 11/15/2005 F - Formal Settlement  
4. 03001 Serious 5174 C 11/01/2005 12/06/2005 $675 $6,750 $0 11/15/2005 F - Formal Settlement  
5. 04001 Serious 5174 D 11/01/2005 12/06/2005 $675 $9,375 $0 11/15/2005 F - Formal Settlement  
6. 05001 Serious 23950051 A 11/01/2005 12/06/2005 $335 $3,375 $0 11/15/2005 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201119831
Event: 05/03/2005
Two Employees Are Injured in Pharmaceutical Flash Fire

On May 3, 2005, Employees #1 and #2 were pouring ingredients into a large blender at Pharmavite; a manufacturer of vitamins in gelatin, tablet and caplet forms. The blender tumbled to make a homogenous mixture of the ingredients. When ingredients were to be added, the mixer would be stopped with the opening at the top. Employees would then attach an electric circular shaker box that vibrated to break up the powder as it went down into the blender. The shaker box had a local exhaust system that was made of plastic material throughout. A plastic coated conductor within the plastic pipe served to maintain the integrity of the pipe. There was no means of bonding or grounding. Employees #1 and #2 were injured when they each poured an ingredient into the blender at the same time, a dust deflagration (flash fire) occurred and flames came out of the blender. The employees were hospitalized at Sherman Oaks Burn Center for burns on their hands and backs. The exact source of the ignition could not be determined.

Keywords: BURN, STATIC ELECTRICITY, DUST, FIRE, MIXER, BACK, EXPLOSION, BONDING, GROUNDING ELECTRODE, HAND

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300829553 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close