Inspection Detail
Inspection: 300828860 - Hector'S Plumbing
Inspection Information - Office: Van Nuys District Office
Site Address:
Hector'S Plumbing
14401 Brimhall Road
Bakersfield, CA 93314
Mailing Address:
5640 District Blvd, Bakersfield, CA 93313
Union Status: NonUnion
SIC:1711
NAICS: 238220/ Plumbing, Heating, and Air-Conditioning Contractors
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/28/2005
Emphasis: S:Construction (Cship)
Case Closed: 08/01/2005
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 361372238 |
Investigation Summary
At 1:30 p.m. on February 21, 2005, Employee #1 was using a forklift to unload a truck at his employer's plumbing shop. While maneuvering a bundle of plastic pipe (1-in. to 2-in.-diameter, 20-ft long, weighing approximately 2,000 to 3,000 lbs.), the pipe became stuck on the truck bed's side rails. Employee #1 dismounted the forklift and tried to dislodge the pipe by pulling on the side of truck. When the load moved, his left hand became caught between the pipe and the truck rail. Employee #1 was treated at Mercy Southwest Hospital for serious crushing injuries to his third and fourth finger tips. The tip of his left third finger was amputated. There were no witnesses to the accident.
Keywords: AMPUTATED, FINGER, CAUGHT BETWEEN, CRUSHED, LACERATION, TRUCK, OFF LOADING, PIPE, PLUMBING, HAND
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 300828860 | Non Hospitalized injury | Amputation | Sales workers, parts |