Inspection Detail
Inspection: 300828423 - Select Personnel
Inspection Information - Office: Van Nuys District Office
Site Address:
Select Personnel
116 E Main St
Taft, CA 93268
Mailing Address:
1528 Chapala St, Santa Barbara, CA 93101
Union Status: NonUnion
SIC:7363
NAICS: 561320/Temporary Help Services
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 04/29/2005
Planning Guide: Health-Manufacturing
Emphasis:
Case Closed: 05/04/2005
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362528333 |
Investigation Summary
At approximately 9:45 a.m. on November 2, 2004, Employee #1, a contract employee, was cleaning oil field pumps with a high pressure hot water gun spray nozzle. Employee #1 was startled by another employee crossing the work area, and he subconsciously lowered the high pressure hot water gun spray nozzle, and consequently, passed the gun spray nozzle through his right foot boot area. The high pressure hot water spray penetrated Employee #1's right rubber boot causing an injury to his right foot. Employee #1 thought it was not a serious injury at the time of the incident and treated himself at his home. The pain in his right foot became unbearable and Employee #1 reported the accident on November 4, 2005, to the contracting employer who then reported it to Employee #1's employer. Employee #1 was sent to a company clinic where he was referred to a Burn Center Hospital. Employee #1 was diagnosed with second and third degree burns to his right foot area. Employee #1 was admitted on November 5, 2005, and hospitalized for approximately 14 days.
Keywords: BURN, HIGH PRESSURE, OIL WELL SERVICING, FOOT, HOT WATER
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 300828423 | Hospitalized injury | Burn/Scald(Heat) | Laborers, except construction |