Powered by GoogleTranslate

Inspection Detail

Inspection: 300827185 - American Fruit Processor

Inspection Information - Office: Van Nuys District Office

 

Inspection Nr: 300827185
Report ID: 0950643
Date Opened: 05/20/2004

Site Address:
American Fruit Processor
10725 Sutter Ave.
Pacoima, CA 91331

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:2087

NAICS: 311999/All Other Miscellaneous Food Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/16/2004

Emphasis:

Case Closed: 07/08/2006


Related Activity
Type Activity Nr Safety Health
Accident 362515595
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $0 $0 $0 $795 $0 $795
Current Penalty $0 $0 $0 $795 $0 $795
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3329 D 11/16/2004 12/03/2004 $420 $420 $0 -  
2. 01002 Other 3203 B02 11/16/2004 12/03/2004 $375 $375 $0 -  

Investigation Summary

Investigation Nr: 201117967
Event: 05/03/2004
Employee Is Burned by Discharge of Hot Water

At approximately 9:00 a.m. on May 3, 2004, Employee #1, a new employee, was performing an assigned task of koshering a tank in the attempt to prepare it for the production of juice. The process of koshering a tank is an additional step beyond the normal cleaning of the tanks. During the koshering process, water at 180 degrees Fahrenheit, is pumped into the tank. The water is pumped from a pump, through food grade flexible hose and then up a vertical pipe on the inlet side of the tank. The water flows through spray balls within the tanks and sprays the interior of the tank. The tank is drained and the hose connection to the inlet side of the tank is opened a small amount to allow the water within the vertical column to drain in a controlled manner to the floor. When the water has drained from the inlet column, the hose is fully disconnected. Employee #1 had been shown how to kosher a tank and had successfully cleaned the first of two identical tanks. He had completed the koshering of tank T-1 and was in the process of releasing the hose. As he opened the hose connection, an uncontrolled release of hot water from the inlet column scalded him, causing thermal burns to his right leg. He was taken to the hospital, treated and released. He was later readmitted to the burn unit for surgery because his wound was not healing properly.

Keywords: BURN, CLEANING, HOSE, INEXPERIENCE, TANK, HOT WATER, LEG

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300827185 Hospitalized injury Burn/Scald(Heat) Production helpers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.