Inspection Detail
Inspection: 300814068 - Santa Barbara Infrared
Inspection Information - Office: Labor Enforcement Task Force (Letf) Unit - South
Site Address:
Santa Barbara Infrared
312 Nopal, Unit A
Santa Barbara, CA 93101
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3861
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 01/09/2003
Planning Guide: Health-Manufacturing
Emphasis:
Case Closed: 01/09/2003
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 101092575 |
Investigation Summary
On November 7, 2002, Employee #1 was working for Santa Barbara Infrared, Inc., at 312-A North Nopal Street in Santa Barbara, California. Santa Barbara Infrared manufactures lenses for infrared applications in the aerospace industry. Employee #1 had forgotten to remove a plastic plug from a concrete block before placing it in a curing oven. The curing process begins at a relatively low temperature which is slowly increased to 500 degrees Fahrenheit. The plug was made of a product called Delrin which, per its Material Safety Data Sheet, will form formaldehyde at temperatures greater than 446 degrees Fahrenheit. Employee #1 was taken to Occupational Medicine Center in Santa Barbara, California after the exposure accident and received first aid treatment for headache, dry and sore throat, and burning nostrils. Employee #1's treatment did not require hospitalization. Drager tube sampling did not detect formaldehyde in the area surrounding the oven.
Keywords: THROAT, HEADACHE, OVEN, INHALATION, NOSE, FORMALDEHYDE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 300814068 | Non Hospitalized injury | Other | Solderers and brazers |