Inspection: 300799855 - Sunny Cal Farms

Inspection Information - Office: Fresno District Office

 

Inspection Nr: 300799855
Report ID: 0950625
Date Opened: 08/07/2000

Site Address:
Sunny Cal Farms
10425 S Kings River Rd
Reedley, CA 93654

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:0723

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 08/07/2000

Emphasis: S:Agriculture (Aship)

Case Closed: 03/23/2009


Related Activity
Type Activity Nr Safety Health
Accident 362285355
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $18,000 $0 $0 $0 $0 $18,000
Current Penalty $4,000 $0 $0 $0 $0 $4,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5155 C01 A 01/30/2001 02/02/2001 $4,000 $18,000 $0 02/26/2001 J - ALJ Decision  

Investigation Summary

Investigation Nr: 201082682
Event: 08/05/2000
Employee suffers from by carbon monoxide exposure

On August 5, 2000, Employee #1 and 19 coworkers were in a cold storage facility used to recondition fruit. They had begun that morning in cold storage room # 3, and continued throughout the day. At approximately 5:00 p.m., Employee #1 drove a propane-fired forklift into the room to pull out pallets of empty boxes. He worked with the forklift in the room for at least an hour. When the first employees began to complain of headaches, the night foreman provided aspirin. Then other employees became nauseated and began vomiting. Emergency services was called and EMS personnel quickly identified the cause of the illness. A firefighter collected an air sample with a direct reading instrument and found a carbon monoxide level of approximately 70 ppm. The company undertook immediate remedial action by instructing employees to use only electric forklifts in the cold storage rooms, and by installing carbon monoxide detectors in room # 3. The level of illness experienced by the employees, and the observations of the firefighter, indicated that the employees were exposed to excessive amounts of carbon monoxide. The cold storage room was designed to maintain a steady temperature without the introduction of fresh air. Vent fans were installed but were not in use because pulling air into the cold rooms would have dropped the temperature below the required 60 to 70 degrees F. At the time of the accident, the room had no general ventilation. Although this conditions had been rectified by the time of the inspection, the employer was cited for a serious, accident-related violation of T8CCR 5155(c)(1)(a).

Keywords: VENTILATION, WORK RULES, INHALATION, INDUSTRIAL TRUCK, EXHAUST FUMES, CHEMICAL VAPOR, POISONING, OVEREXPOSURE, CARBON MONOXIDE, CHEMICAL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300799855 Non Hospitalized injury Other Laborers, except construction
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.