Inspection Detail
Inspection: 300798097 - Av Tub & Top
Inspection Information - Office: Fresno District Office
Site Address:
Av Tub & Top
44425 N Sierra Hwy
Lancaster, CA 93534
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3088
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 09/22/1999
Emphasis:
Case Closed: 10/31/2000
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 361691470 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | 2 | |||
Current Violations | 2 | 2 | ||||
Initial Penalty | $3,000 | $0 | $0 | $100 | $0 | $3,100 |
Current Penalty | $0 | $0 | $0 | $100 | $0 | $100 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 342 A | 02/24/2000 | 02/29/2000 | $0 | $100 | $0 | J - ALJ Decision | ||
2. | 02001 | Other | 5416 C | 02/24/2000 | 03/27/2000 | $100 | $3,000 | $0 | 03/23/2000 | J - ALJ Decision |
Investigation Summary
On August 19, 1999, Employee #1 was working on a remodel job of a residential bathroom. A sprayer was being used to apply a coating process to the tub. Employee #1 was seriously burned in a flash fire that occurred while he was applying this coating. The coating was found to be highly flammable and the explosive vapors which accumulated in the bathroom were ignited by the spray rig. Employee #1 suffered third degree burns over twenty percent of his body.
Keywords: ENCLOSED SPACE, VAPOR, PPE, FIRE, IGNITION SYSTEM, EXPLOSION, CHEMICAL
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 300798097 | Hospitalized injury | Burn/Scald(Heat) | Painters, construction and maintenance |