Inspection: 300780228 - Pouk & Steinle Inc

Inspection Information - Office: Long Beach District Office

 

Inspection Nr: 300780228
Report ID: 0950642
Date Opened: 10/17/2002

Site Address:
Pouk & Steinle Inc
Brightwood & Hillside St
Monterey Park, CA 91754

Mailing Address:
2520 Rubidoux St Po Box 3039, Riverside, CA 92519

Union Status: Union

SIC:1731

NAICS: 238210/Electrical Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/26/2003

Planning Guide: Safety-Construction

Emphasis: S:Construction (Cship)

Case Closed: 09/13/2010


Related Activity
Type Activity Nr Safety Health
Accident 101052850
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 2 1 3
Initial Penalty $29,250 $0 $0 $750 $0 $30,000
Current Penalty $22,500 $0 $0 $750 $0 $23,250
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A 03/26/2003 04/08/2003 $750 $750 $0 10/29/2003 F - Formal Settlement  
2. 02001 Serious 29400002 A 03/26/2003 04/03/2003 $22,500 $22,500 $0 10/29/2003 F - Formal Settlement  
3. 03001 Serious 2940 A 03/26/2003 04/03/2003 $0 $6,750 $0 10/29/2003 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201056934
Event: 09/30/2002
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE

A crew consisting of two power line workers, their supervisor, and a ground worker was assigned to repair a pin on 4-volt overhead power line. The crew held a job briefing, discussing the conditions of the job, and then started to work. In the process of performing their assigned task, they discovered more damaged equipment, including a splintered arm supporting a 16-kilovolt power line, which they also replaced. After the crew completed the repairs, they removed all the rubber insulating line hose and blankets. Right before leaving the area for the next job, the supervisor noticed an infraction of the State's public safety regulations involving the ground molding. The crew supervisor decided that this also needed correcting through replacement of the wood molding. He also decided that one power line worker could perform the task since the supervisor anticipated that the task would not involve the primary area or minimum approach distances. He assigned the task to a journeyman power line worker with 5 to 6 years of experience. The first section of the molding from the bottom was new, so the power line worker started the repair about 1.5 meters above the ground. The repair extended to a point below the primary crossarm. Working from an aerial lift, the employee was in this area, pulling staples with a metal pry bar, when he contacted the 4000-volt power line and sustained an electric shock and burns. He fell into the aerial lift bucket. A power line worker on the ground moved the aerial lift away from the power line using the lower controls. The injured employee was then able to lower the bucket and exit on his own. He was hospitalized in a burn center for burns to the thumb and index finger on his left hand; the thumb, palm, and ring and little finger on his right hand; and, on his right shoulder, from his triceps to his elbow. (He was in intensive care for 1 week and remained hospitalized for an additional 2 weeks.) He later returned to the hospital for more surgery, resulting in additional hospitalization.

Keywords: BURN, ELEC PROTECT EQUIP, OVERHEAD POWER LINE, ELECTRICAL, POWER LINE WORKER, E PTD, ELEC UTILITY WORK, ELECTRIC SHOCK, AERIAL LIFT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300780228 Hospitalized injury Burn/Scald(Heat) Supervisors; electricians & power transm. install.
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.