Powered by GoogleTranslate

Inspection Detail

Inspection: 300778800 - Exide Technologies

Inspection Information - Office: Long Beach District Office

 

Inspection Nr: 300778800
Report ID: 0950642
Date Opened: 02/15/2002

Site Address:
Exide Technologies
2700 S Indiana St
Vernon, CA 90023

Mailing Address:
, , 00000

Union Status: Union

SIC:3692

NAICS: 335912/Primary Battery Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/08/2002

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 06/25/2005


Related Activity
Type Activity Nr Safety Health
Accident 101051142
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 2 3
Current Violations 3 3
Initial Penalty $18,000 $0 $0 $655 $0 $18,655
Current Penalty $0 $0 $0 $1,180 $0 $1,180
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 07/09/2002 07/23/2002 $300 $375 $0 08/09/2002 F - Formal Settlement  
2. 01002 Other 3203 B 07/09/2002 07/23/2002 $280 $280 $0 08/09/2002 F - Formal Settlement  
3. 02001 Other 3328 G 07/09/2002 07/23/2002 $600 $18,000 $0 08/09/2002 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201056371
Event: 02/11/2002
Employee injured in blast furnace explosion

Employee #1 was training another employee on the process of tapping and pouring molten lead (the employer is involved in the smelting of lead). At the time of the accident, Employee #1 had just tapped the slag and was walking along the south side to observe the pouring operation. He felt the pressure of hot slag and dust from the furnace on his legs and immediately jumped into an empty kettle before a second larger explosion occurred. Employee #1 sustained second and third degree burns from his thighs down both legs and was transported to LAC/USC Medical Center where he was admitted and treated for his injuries. Later, he received treatment at the Grossman Burn Center in Sherman Oaks. The water jacket showed evidence of a hole and the furnace wall weakened, leading it to blow out the southeast corner. Inspection and maintenance of the furnace is needed periodically, however, the employer did not perform periodic inspections of the blast furnace. The furnace was only inspected when it showed signs of damage, such as glowing bricks.

Keywords: BURN, INADEQUATE MAINT, MOLTEN SLAG, BLAST FURNACE, EXPLOSION, MOLTEN METAL, MELTING FURNACE, LEG

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300778800 Hospitalized injury Burn/Scald(Heat) Machinery maintenance occupations
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.