Inspection: 300776200 - California Institute Of Technology
Inspection Information - Office: Long Beach District Office
Site Address:
California Institute Of Technology
1200 E California Bl
Pasadena, CA 91125
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:8221
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/05/2001
Emphasis:
Case Closed: 02/14/2002
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362612319 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | ||||||
| Initial Penalty | $18,000 | $0 | $0 | $0 | $0 | $18,000 |
| Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 2717 | 03/05/2001 | 03/19/2001 | $0 | $18,000 | $0 | 06/01/2001 | F - Formal Settlement | Citation has been deleted. |
Investigation Summary
A graduate research assistant was working in a State university laboratory used by the university's Physics Department for niobium research. The employee was working with an evaporator chamber to anneal niobium at 1500 degrees Celsius and 1E-8 Torr. The annealing process had finished, and the employee was placing a plastic isolation tent around the evaporator chamber. As he reached around the chamber, the pinky finger on his right hand touched an energized part on the evaporator. The 4000-volt circuit part was located inside a 76-millimeter-tall, 38-millimeter-diameter plastic cylinder that was open on top. The energized part was not completely guarded against contact. The employee received an electric shock and burns. He was hospitalized for his injuries, and his burns required skin grafts.
Keywords: BURN, E GI V, ELECTRICAL, UNGUARDED LIVE PARTS, ELEC CIRC PART--MISC, ELECTRIC SHOCK
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 300776200 | Hospitalized injury | Burn/Scald(Heat) | Operations & systems researchers and analysts |