Inspection Detail
Inspection: 300772944 - Northern Store Services
Inspection Information - Office: Nv-E-Las Vegas 0953220
Site Address:
Northern Store Services
2255 N. Las Vegas Blvd.
North Las Vegas, NV 89030
Mailing Address:
6110 N.W. Grand Ave., Glendale, AZ 85301
Union Status: NonUnion
SIC:7349
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/13/1998
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 06/09/1998
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 101040707 | ||
| Complaint | 201028149 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 1 | 3 | |||
| Current Violations | 1 | 1 | 2 | |||
| Initial Penalty | $3,000 | $0 | $0 | $0 | $0 | $3,000 |
| Current Penalty | $1,200 | $0 | $0 | $0 | $0 | $1,200 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 19100038 B01 | 05/04/1998 | 06/19/1998 | $0 | $1,500 | $0 | I - Informal Settlement | Citation has been deleted. | |
| 2. | 01002A | Serious | 19101200 E01 | 05/04/1998 | 06/19/1998 | $1,200 | $1,500 | $0 | I - Informal Settlement | ||
| 3. | 01002B | Serious | 19101200 G08 | 05/04/1998 | 06/19/1998 | $0 | $0 | $0 | I - Informal Settlement | ||
| 4. | 01002C | Serious | 19101200 H01 | 05/04/1998 | 06/19/1998 | $0 | $0 | $0 | I - Informal Settlement | ||
| 5. | 01002D | Serious | 19100038 B05 | 05/04/1998 | 06/19/1998 | $0 | $0 | $0 | I - Informal Settlement | ||
| 6. | 02001 | Other | 618038301 | 05/04/1998 | 06/19/1998 | $0 | $0 | $0 | I - Informal Settlement |
Investigation Summary
Employee #1 was using a propane-powered floor burnisher in an equipment storage stockroom at the back of a drugstore. A fire erupted and he suffered burns to his face, neck, and hands, for which he was hospitalized. A flammable liquid may have been applied on or near the burnisher's fresh air intake area. The burnisher's sealed 12-volt DC battery required recharging and the flammable vapors may have been ignited by a source associated with the burnisher.
Keywords: BURN, FLAMMABLE LIQUID, FLAMMABLE VAPORS, WORK RULES, FIRE, PROPANE, SPARK, CHEMICAL VAPOR, HAND, CHEMICAL
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 300772944 | Hospitalized injury | Burn/Scald(Heat) | Supervisors, cleaning and building service workers |