Inspection Detail
Inspection: 300761426 - Robinsons May Co
Inspection Information - Office: Long Beach District Office
Site Address:
Robinsons May Co
300 Los Cerritos Mall
Cerritos, CA 90701
Mailing Address:
6160 Laurel Canyon Blvd, North Hollywood, CA 91606
Union Status: NonUnion
SIC:5311
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/23/2001
Emphasis:
Case Closed: 08/16/2004
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362027708 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 2 | ||||
| Current Violations | 2 | 2 | ||||
| Initial Penalty | $23,060 | $0 | $0 | $0 | $0 | $23,060 |
| Current Penalty | $0 | $0 | $0 | $1,310 | $0 | $1,310 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 1675 L | 10/24/2001 | 10/29/2001 | $560 | $5,060 | $0 | 11/28/2001 | F - Formal Settlement | |
| 2. | 02001 | Other | 23200002 A | 10/24/2001 | 11/12/2001 | $750 | $18,000 | $0 | 11/28/2001 | F - Formal Settlement |
Investigation Summary
Employee #1 was working as a maintenance mechanic or maintenance engineer for a large department store. He was working from an aluminum ladder, attaching the leads of a voltmeter to the load side of a 480-volt disconnect switch to check for voltage. Although the system was energized, he was not wearing flame-resistant clothing, rubber insulating gloves, or suitable eye protection. An electrical fault occurred, and the ensuing electric arc knocked Employee #1 to the floor. Investigators found a screwdriver at the accident scene that they believed caused the fault. Employee #1 sustained second-degree burns to his right arm and first-degree burns to his face. He was hospitalized for 2 days for treatment of blisters and monitoring of vital signs. Normal skin color in the burned area of his arm was supposed to return in about 1 year.
Keywords: BURN, E GI II, ELECTRIC ARC, MAINTENANCE, ELECTRICAL, ELECTRIC SWITCH, PPE, TEST EQUIPMENT, SKIN, ELECTRICAL FAULT
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 300761426 | Hospitalized injury | Electric Shock | Electrical power installers and repairers |