Inspection: 300687464 - Mp Industrial Coatings, Inc

Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health

 

Inspection Nr: 300687464
Report ID: 0352440
Date Opened: 07/08/1997

Site Address:
Mp Industrial Coatings, Inc
1000 Brandon Shores Road
Baltimore, MD 21226

Mailing Address:
2301 Grays Road, Sparrows Point, MD 21222

Union Status: Union

SIC:1721

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/23/1997

Emphasis:

Case Closed: 01/05/2011


Related Activity
Type Activity Nr Safety Health
Accident 100962489
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 1 5
Current Violations 4 1 5
Initial Penalty $4,900 $0 $0 $0 $0 $4,900
Current Penalty $1,500 $0 $0 $0 $0 $1,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260451 D10 I 08/22/1997 08/26/1997 $375 $1,225 $0 I - Informal Settlement  
2. 02001 Serious 19260451 G03 I 08/22/1997 08/26/1997 $375 $1,225 $0 I - Informal Settlement  
3. 02002 Serious 19260502 D23 08/22/1997 08/26/1997 $375 $1,225 $0 I - Informal Settlement  
4. 03001A Serious 19261053 B16 08/22/1997 08/26/1997 $375 $1,225 $0 I - Informal Settlement  
5. 03001B Serious 19261053 A07 08/22/1997 08/26/1997 $0 $0 $0 I - Informal Settlement  
6. 04001 Other 19260503 B01 08/22/1997 08/27/1997 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 200961217
Event: 07/08/1997
Employee injured in fall when suspended cable fails

Employee #1 was sandblasting and painting the interior of a surge water tank from a single point suspension scaffold. The scaffold was suspended from a 5/16 in. wire rope that failed approximately 20 in. below its attachment point. Employee #1's fall was arrested by his fall protective equipment, and he sustained only a bruise on his arm. The wire rope used to suspend the scaffold was badly damaged, with numerous broken wires, worn and flattened strands, an area that was coiled, a kink with the core protruding, and a number of areas where the rope was bent. Despite its poor condition, the cable had not been removed from service.

Keywords: WIRE ROPE, INADEQUATE MAINT, BROKEN CABLE, CONSTRUCTION, EQUIPMENT FAILURE, FALL, ARM, SCAFFOLD RIGGING, CONTUSION, SCAFFOLD

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300687464 Non Hospitalized injury Bruise/Contus/Abras Painters, construction and maintenance
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.