Inspection Detail
Inspection: 300687464 - Mp Industrial Coatings, Inc
Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health
Site Address:
Mp Industrial Coatings, Inc
1000 Brandon Shores Road
Baltimore, MD 21226
Mailing Address:
2301 Grays Road, Sparrows Point, MD 21222
Union Status: Union
SIC:1721
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/23/1997
Emphasis:
Case Closed: 01/05/2011
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 100962489 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 4 | 1 | 5 | |||
| Current Violations | 4 | 1 | 5 | |||
| Initial Penalty | $4,900 | $0 | $0 | $0 | $0 | $4,900 |
| Current Penalty | $1,500 | $0 | $0 | $0 | $0 | $1,500 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19260451 D10 I | 08/22/1997 | 08/26/1997 | $375 | $1,225 | $0 | I - Informal Settlement | ||
| 2. | 02001 | Serious | 19260451 G03 I | 08/22/1997 | 08/26/1997 | $375 | $1,225 | $0 | I - Informal Settlement | ||
| 3. | 02002 | Serious | 19260502 D23 | 08/22/1997 | 08/26/1997 | $375 | $1,225 | $0 | I - Informal Settlement | ||
| 4. | 03001A | Serious | 19261053 B16 | 08/22/1997 | 08/26/1997 | $375 | $1,225 | $0 | I - Informal Settlement | ||
| 5. | 03001B | Serious | 19261053 A07 | 08/22/1997 | 08/26/1997 | $0 | $0 | $0 | I - Informal Settlement | ||
| 6. | 04001 | Other | 19260503 B01 | 08/22/1997 | 08/27/1997 | $0 | $0 | $0 | I - Informal Settlement |
Investigation Summary
Employee #1 was sandblasting and painting the interior of a surge water tank from a single point suspension scaffold. The scaffold was suspended from a 5/16 in. wire rope that failed approximately 20 in. below its attachment point. Employee #1's fall was arrested by his fall protective equipment, and he sustained only a bruise on his arm. The wire rope used to suspend the scaffold was badly damaged, with numerous broken wires, worn and flattened strands, an area that was coiled, a kink with the core protruding, and a number of areas where the rope was bent. Despite its poor condition, the cable had not been removed from service.
Keywords: WIRE ROPE, INADEQUATE MAINT, BROKEN CABLE, CONSTRUCTION, EQUIPMENT FAILURE, FALL, ARM, SCAFFOLD RIGGING, CONTUSION, SCAFFOLD
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 300687464 | Non Hospitalized injury | Bruise/Contus/Abras | Painters, construction and maintenance |
Translate